GB
Page 36 of 64
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Fig. 63
1
5
4
2
2
6
7
8
9
KEY
1 – Total inner weight
2 – Arrows to help positioning manually the wheel
(see Par. 15.3.2) in correction weight fitting point
3 – N° of current user
4 – Total outer weight
5 – R e t u r n t o i n i t i a l p r o g r a m p h a s e
(RED) (F1)
6 – Display next row of keys (MATCHING PROCE-
DURE and HIDDEN WEIGHTS) (YELLOW) (F2)
7 – Displays exact unbalance (resolution 1 g instead
of 5 g) (CENTRAL)
8 – Displays the previous screen page (BLUE) (F3)
9 – Performs spin with protection guard closed
(GREEN) (F4)
10 – Function key used for recalculation program
(see Par. 15.5) (B)
3
10
Fit the adhesive weight on wheel outer side. The outer
side weight must be positioned by hand on the vertical
(see
Fig. 64
).
Fig. 64
To fit the adhesive weight on the inner part of the wheel,
turn the wheel in the direction of the arrows until the
correct position is reached (the two arrows must be
horizontal).
Remove the automatic gauge and fit the adhesive weight
in the pliers as shown in
Fig. 65
, using a weight of pre-
determined value (the example in
Fig. 63
shows 35 g).
Fig. 65
Fit the adhesive weight in the
pliers of the automatic rod
An arrow that appears on the page shows the weight is
coming close to correction position. When two fixed ar-
rows are achieved (see
Fig. 66
) fit the adhesive weight
on the inner side in the position where the weight pliers
touch the wheel.
Fig. 66
On reaching the 2 fixed ar-
rows, fit the adhesive weight
The fact that the weight fitting position is no longer at
12 o’ clock (see
Fig. 67
) is automatically offset.
If the adhesive weight has to be hidden behind spokes,
refer to “weights hidden behind spokes mode” in
Chapt. 18.
G2.124R - GP2.124R
RAVAGLIOLI S.p.A.
1297-M010-0_R