EN
Page 62 of 91
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Press the brake pedal and fit the adhesive weight inside
pliers as shown in
Fig. 62
.
Fig. 62
Fit the adhesive weight
in the pliers of the gauge rod
Pull out the gauge rod until the arrows (
Fig. 63 ref. 6
)
turn green.
Fig. 63
Fit weight on the position
where pliers touches the wheel
At the end of the procedure, the wheel balancing condi-
tions can be checked by performing a trial spin.
The ECO-WEIGHT procedure has now been completed.
IMMEDIATELY AFTER HAVING
SELECTED THE ECO-WEIGHT
PROCEDURE, YOU CAN KNOW
IN ADVANCE THE TWO DYNAMIC
UNBALANCES AND THE STATIC
RESIDUE IN ORDER TO DECIDE
WHETHER IT IS CONVENIENT TO
CONTINUE (SEE FIG. 61).
IF BOTH DYNAMIC UNBALANCES
AND STATIC RESIDUE ARE SHOWN
AS WHITE VALUES ON THE MONI-
TOR, THIS MEANS THAT THE
PROGRAM HAS DECIDED THAT IT
IS BETTER TO CONTINUE. WHILE
IF, ON THE OTHER HAND, ONE OR
MORE VALUES ARE YELLOW, THE
PROGRAM SUGGESTS USING THE
STANDARD ALU-S PROCEDURE.
G3.150 - GP3.150 - G3.150S - GP3.150S - G3.150WS - GP3.150WS - G3.150WSPLUS - GP3.150WSPLUS - G3.150SA - G3.150WSA
RAVAGLIOLI S.p.A.
1297-M058-00