9.3.3 Fitting of external data gauge (standard
for G3.140RS - GP3.140RS versions)
(optional for G3.140R - GP3.140R ver-
sions)
1. Unscrew the fastening screws of the equalizer's
support (
Fig. 13 ref. 1
), being very careful about
holding the same support.
2. Unscrew the 3 screws (
Fig. 13 ref. 2
) to the gauge
bracket (
Fig. 13 ref. 3
) and in the special inserts
placed on the rear side of the frame.
Lock the gauge arm (
Fig. 13 ref. 4
) by screwing
the 2 screws provided (
Fig. 13 ref. 5
). Lock these
screws with the nuts (
Fig. 13 ref. 6
) so that the
mandrel and the gauge arm are levelled out (see
Fig. 14
).
Fig. 13
3. Also make sure the gauge tip (
Fig. 14 ref. 1
) is
positioned at the centre of the mandrel.
Fig. 14
4. Connect connector (
Fig. 15 ref. 1
) of the cable com-
ing from inside the machine to connector (
Fig. 15
ref. 2
) of the cable coming from the gauge arm. Fit
the section of the cable with the connectors inside
the arm (
Fig. 15 ref. 3
).
5. Fasten the cable with clamps.
6. Enable the external data gauge and carry out the
device's calibration.