-In case of violent wind particular attention must be taken against tilting of the appliance; Keep the
appliance at least 1m from the gas cylinder.
-The injector is installed by the manufacturer only.
Do not connect the gas cylinder directly to the appliance without regulator. Use only the type of gas
and the type of cylinder specified in the instructions.
A regulator(compliees with EN16129:2013 and the national regulation)
of the correct pressure corresponding to the appliance category.
Use 30mbar regulator for butane/propane under the category I3B/P(30).
Use 30mbar regulator for butane under the category I3+(28-30/37).
Use 37mbar regulator for propane under the category I3+(28-30/37).
Use 50mbar regulator for butane/propane under the category I3B/P(50).
It's recommended to use flexible hose that approved by EN16436: 2014.
CAUTION
PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION.
1.
Do not use the patio heater for indoors, as it may cause personal injury or property damage.
2.
This outdoor heater is not intended to be installed on recreational vehicles and/or boats.
3.
Installation and repair should be done by a qualified service person.
4.
Improper installation, adjustment, alteration can cause personal injury or property damage.
5.
Do not attempt to alter the unit in any manner.
6.
Never replace or substitute the regulator with any regulator other than the factory-suggested
replacement.
7.
Do not store or use gasoline or other flammable vapors or liquids in the heater unit.
8.
The whole gas system, hose, regulator, pilot or burner should be inspected for leaks or damage
before use, and at least annually by a qualified service person.
9.
All leak tests should be done with a soap solution. Never use an open flame to check for leaks.
10.
Do not use the heater until all connections have been leak tested.
11.
Turn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve OFF. If leak
is at Hose/
Regulator connection: tighten connection and perform another leak test. If bubbles continue
appear
ing should be returned to hose’s place of purchase. If leak is at Regulator/Cylinder Valve
connection: disconnect, reconnect, and perform another leak check. If you continue to see
bubbles after several attempts, cylinder valve is defective and should be r
eturned to cylinder’s
place of purchase.
12.
Do not transport heater while it’s operating.
13.
Do not move the heater after it has been turned off until the temperature has cooled down.
14.
Keep the ventilation opening of the cylinder enclosure free and clear of debris.
15.
Do not paint the radiant screen, control panel or top canopy reflector.
16.
Control compartment, burner and circulation air passageways of the heater must be kept
clean.
Frequent cleaning may be required as necessary.
17.
The LP tank should be turned off when the heater is not in use.
18.
Check the heater immediately if any of the following occurs:
-
The heater does not reach temperature.
-
The burner makes popping noise during use (a slight noise is normal when the burner
is extinguished).
-
Smell of gas in conjunction with extreme yellow tipping of the burner flames.
19.
The LP regulator/hose assembly must be located out of pathways where people may trip over
it or in area where the hose will not be subject to accidental damage.
20.
Any guard or other protective device removed for servicing the heater must be replaced before
operating the heater.
Summary of Contents for OG-300
Page 25: ...ASSEMBLY PARTS ASSEMBLY PROCEDURES...
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......