Summary of Contents for iForks-32 XT

Page 1: ...PRESENTED BY JPBOWLIN COM 817 332 8116 J P Bowlin is a quality driven Calibration Company that has provided calibration repair and sales of all types of weighing and measurement products since 1931 ...

Page 2: ... product is 100 recyclable on the basis that the parts are processed and disposed of in the right manner More information can be found on our website www ravas com Rev 20191203 Printing Typographical errors and model changes reserved USER MANUAL iForks 32 XT 1 USER MANUAL ...

Page 3: ... instructions or from negligent operation or assembly even if this is not expressly stated in this instruction manual In light of our policy of continuous improvement it is possible that details of the product may differ from those described in this manual For this reason these instructions should only be treated as guidelines for the installation of the relevant product This manual has been com p...

Page 4: ...ttery packs 13 4 4 Changing the batteries of the indicator 14 5 Use 15 5 1 Use accurate weighing 15 5 2 Level correction option 16 5 3 Bluetooth communication 17 5 3 1 Establish Bluetooth communication and weigh 17 5 3 2 Auto reconnect function 18 5 4 Auto shut off indicator 19 5 5 Auto shut off iForks 32 XT 20 5 6 Indicator functions 21 5 7 Error messages 23 5 8 Net Tare Gross weight 24 5 8 1 Net...

Page 5: ...esence of the indicator in the cabin Any modifications done to the system must be approved in writing by the supplier prior to any work being completed It is the sole responsibility of the purchaser to train their own employees in the proper use and maintenance of this equipment Do not operate this unit unless you have been fully trained in its capabilities Check the accuracy of the scale on a reg...

Page 6: ...th water without rubbing your eyes and seek medical advice immediately The charging of the battery will be stopped automatically When due to what cause the battery is not fully charged after 8 hours LED of the charger doesn t become green immediately unplug the battery from the holder to stop charging Battery or charger does not work properly exchange battery or charger Storing and or using the ba...

Page 7: ...is not used for a longer period make sure the battery has approximately 70 of the battery capacity remaining Take care not to let the battery become completely empty by charging it every 6 months Store the battery separated from the weighing system in an indoor place approx 10 C 20 C where it is not exposed to direct sunlight or rain Battery life The battery is a consumable item The battery will g...

Page 8: ...tem setup 3 1 Installing the iForks 32 XT The standard forks must be taken off the carriage plate The iForks 32 XT are placed on the carriage plate 3 2 Locking the iForks 32 XT 1 2 USER MANUAL iForks 32 XT 7 ...

Page 9: ...ind a suitable position for the indicator 1 at the cabin s roof 2 on the right side of the cabin mounted onto a side rail 3 on the dashboard Installation of the indicator bracket support 3 2 1 S13 1 2 S5 3 USER MANUAL iForks 32 XT 8 ...

Page 10: ...clips down to unlock the battery holders 2 Open the battery holders of both forks 3 Position the battery packs in the battery holders of both forks until the red locking clip shifts up again 4 Close the battery holders of both forks until you hear a click USER MANUAL iForks 32 XT 9 ...

Page 11: ...tically The iForks are ACTIVE when the blue LEDs on both iForks 1 2 flash repeatedly 1 3 2 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Start up the indicator Press the on off key OR Switch on the iForks 32 XT Move the iForks 32 XT quickly in upwards or downwards direction After 5 seconds all electronics are warmed up and you can start weighing USER MANUAL iForks 32 XT 10 ...

Page 12: ...2 NET ID CODE PT TOTAL KG LB CLR 3 sec Switch off the indicator by pressing the on off key for 3 seconds Both forks will switch off automatically The blue LED s SLEEP on both iForks 1 2 will start blinking automatically USER MANUAL iForks 32 XT 11 ...

Page 13: ... blinking in the display The blue LED LOW BATTERY on the relating fork will start blinking very slowly twice every 10 sec The iForks 32 XT will switch off automatically after 10 minutes e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR FUNCTIONALITY BLUE LED DURING POWERING ON ON for 5 sec FULL BATTERY Blink time interval Working mode Once every 1 5 sec Sleep mode Once every 12 sec LOW BATTERY Working...

Page 14: ... the battery packs are completely full The red LED on the adapter will change tot green once the batteries are fully charged NOTE It is not necessary to charge both batteries simultaneously If one battery is charged at a time the charging time will be shorter First position the battery packs inside the charger module then plug the adaptors into the mains voltage 8 hours 1 2 Take out both battery p...

Page 15: ...ove the battery cover of the indicator housing by turning the screw counter clockwise Remove the battery holder and remove the empty batteries Place new batteries in the battery holder and place the battery holder in the housing Be sure the batteries are positioned correctly Check for the polarity Close the battery cover of the indicator housing and lock by turn ing the screw clockwise 1 2 1 2 1 2...

Page 16: ...ghing min 10 C 15 F 0 0 max 40 C 105 F M1 3 5 min OK M1 After 3 to 5 minutes the load cells have reached the operational temperature Don t lift loads before the zero point correction has been executed USER MANUAL iForks 32 XT 15 ...

Page 17: ... e2 e3 F2 F1 α NTEP OK if α 5 3 OIML OK if α 2 Check the zero reading before each weighing Before each weighing it is necessary to check whether the system is unloaded and free If the indicator does not determine the zero point automatically it must be done manually using the 0 key Legal for trade USER MANUAL iForks 32 XT 16 ...

Page 18: ...e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 5 sec System is ready to weigh Before the next weighing check the zero point again Before each weighing check the zero point Before each weighing it is necessary to check whether the system is unloaded and free If the indicator does not determine the zero point automatically it must be done manually using the 0 key OR Switch on the iForks 32 XT Move the i...

Page 19: ...L KG LB CLR If the Bluetooth link between the indicator and forks is lost the indicator will show this error message Just wait for maximum 20 seconds The Bluetooth link will re connect automatically If the Bluetooth link does not re connect remove and replace the batteries of the forks and then restart the indicator ...

Page 20: ...T ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Countdown starts Press any key during countdown to cancel auto shut off and go back to the weighing mode No action Indicator off 6 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR To activate the indicator press the on off key ...

Page 21: ...ff Indicator off e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Restart the indicator Press the on off key e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 2 hour No weighing OR Switch on the iForks 32 XT Move the iForks 32 XT quickly in upwards or downwards direction 8 7 The display automatically returns to its normal weighing mode ...

Page 22: ...ble the weight shown is negative the weight shown is within the zero range the display is showing the net weight displayed weight is in range 1 option multi range displayed weight is in range 2 option multi range displayed weight is in range 3 option multi range Fork 1 Low battery Fork 2 Low battery displayed weight is in kilograms displayed weight is in pounds low bat indicator ...

Page 23: ...e set tare check subtotal and print reset total no function Off switch enter decrease the value of the digit flashing increase the value of the digit flashing shift to the next digit on the left clear entry ID CODE PT TOTAL KG LB CLR Important Operation of a key is not accepted unless the weighing system is stable and the load stable pointer lights up This means that the indicator only executes co...

Page 24: ...gal for trade version action not allowed only legal for trade version audit trail no out of range too few samples for measurement too few samples for measurement Wrong combination of firmwares P96 not set Automatic Automatic after removing weight Automatic Press any key Automatic after correcting input Automatic Automatic Automatic Automatic When action is intended remove jumper JP1 attention afte...

Page 25: ...matic tare 1 2 3 4 EXPLANATION Net 1 Tare 2 Gross 3 1 2 3 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR The indicator is set to zero The NET pointer shows that the tare weight is activated ...

Page 26: ...D CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR The display shows the net value of the weighed load The gross weight is displayed again NOTE for NTEP iForks 32 XT the tare will be erased automatically when the weight returns to gross zero For the next weighing the tare must be activated again ...

Page 27: ...OTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 1000 25 Press ENTER to activate the tare weight Press the T key for 3 seconds Press the up or down key until the desired value is reached Press the up or down key until the desired value is reached 5x 1x 2x ...

Page 28: ...B CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 1000 1000 When the iForks 32 XT are completely unload ed the tare value is displayed negatively The NET pointer lights up NOTE for NTEP iForks 32 XT the tare will be erased automatically when the weight returns to gross zero For the next weighing the tare must be activated again ...

Page 29: ... CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR The gross weight is displayed again NOTE The last used preset tare value will remain in the preset tare memory For re using preset tare value hold the T key for 3 seconds than press Enter ...

Page 30: ... NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 250 250 1000 Press the TOTAL key to add the load weight to the total weight If a printer is installed a printout will be made The gross net and tare weights are printed Press the TOTAL key to add the weight load to the total weight If a printer is installed a printout will be made The gross net and tare weights are print...

Page 31: ...G LB CLR 3 sec 3 sec CLR TOTAL KG LB CLR RESET TOTAL PRINT RESET TOTAL The subtotal can be checked by pressing the TOTAL key for 3 sec 3X NOTE In case the total is not manually used or reset the system will do this automatically as soon as the total number has reached 99 or as soon as the total weight has reached a value of 99999 kg ...

Page 32: ...T ID CODE PT TOTAL KG LB CLR Press the up down key until the desired value is reached The display will show ho_00 or the previous hour time setting The user menu can be entered by pressing the TOTAL key for 10 sec Select TIME in the user menu to change the time e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Press enter to change the time e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Press enter to ...

Page 33: ...T ID CODE PT TOTAL KG LB CLR To accept the new value press enter Press the up down key until the desired value is reached e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Press to change the next digit 11 Repeat the procedure to accept or change the minute setting m_00 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 3 sec 12 3 sec CLR Back to weigh mode ...

Page 34: ... USER MANUAL iForks 32 XT 33 5 11 LB KG switch 1 2 test ...

Page 35: ...OTAL KG LB CLR 10 sec Back to weigh mode Back to weigh mode These user settings can be changed if desired See next pages The user menu can be entered by pressing the TOTAL key for 10 sec EXIT SAVE EXIT WITHOUT SAVING 3 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Press enter to Select CLR a b ...

Page 36: ...ER MANUAL iForks 32 XT 35 Set backlight intensity in Set the auto shut off time indicator delay time in minutes 0 min indicator always on 0 backlight off for saving setting see 3a for saving setting see 3a ...

Page 37: ... C auto on SLEEP not possible 0 0 SLEEP 0 0 A_OFF not possible 0 0 A_OFF 0 0 P60 6 FLT FLT P60 FLT FLT SLEEP 2 30 0 SLEEP 0 0 A_OFF 5 0 0 A_OFF 0 0 RPW ST 320 6v RPW ST 320 truck supply RPW ST 320 auto on RPW ST BLE 320 6v no printer RPW ST BLE 320 truck supply RPW ST BLE 320 auto on SLEEP not possible 0 0 not possible 0 0 A_OFF not possible 0 0 not possible 0 0 P60 6 FLT FLT 6 FLT FLT SLEEP 2 30 ...

Page 38: ...OTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR 10 sec The user menu can be entered by pressing the TOTAL key for 10 sec e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Select to change the setting Press enter to Select Press enter to Select Press to change to Supervisor menu Select to change the setting ...

Page 39: ...tment for the password 5 14 Relay function optional The 3200 indicator has the possibility to setup limit values for relay settings The different options for relay settings are overload on gross weight overload on net weight dosing filling with manual tare start dosing filling with automatic tare start The setup and the activation of the relay settings are explained in the service manual ...

Page 40: ...ive or negative sign and whether it was a calculated net or a measured net For example 0233 5kgC or 00136 lb_ The C stands for calculated and is sent along when a preset tare value was active If there is no preset tare value active a blanc space is put behind the kg or lb 5 Tare weight this number always consists of 5 digits a possible decimal point as part of the 5 digits the unit kg or lb the po...

Page 41: ... user menu can be entered by pressing the TOTAL key for at least 10 sec Press the up down key until the display shows the user setting ALibi Enter the requested alibi number by using the up and down keys and the shift key In this example we enter alibi number 2 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Press enter to Select Press enter to confirm Press enter to confirm ...

Page 42: ... then minutes of the weighing with alibi number 02 Press enter to continue to the month Press enter to continue Press enter to continue to the year Press enter to continue For 0 5 sec the display shows the text Gross Next the display shows the gross weight Press enter to continue to the hour Press enter to continue to the minute ...

Page 43: ... the text tArE or PtArE Next the display shows the tare weight tare weight is measured Ptare weight is keyed in The indicator will automatically return to the user setting Alibi in the user menu For 0 5 sec the display shows the text Code Next the display shows the code used If no code was used the display shows 0 Press enter to search for another weighing or press CLR 2x to return to the normal w...

Page 44: ...file after which it can be imported in a spreadsheet program on a PC From the app you can enter the ID of an operator or device enter tares automatically or manually zero the weighing system Date and time are automatically generated If your Android device has an integrated barcode scanner you can use it to enter product IDs In addition the app makes it possible to download a log file from the RAVA...