ERVICE
S
46
6823346-R3
24
The screen will show an AP value, for example "AP__27".
Press the "Zero" button. The value on the screen is the
percentage of weight used.
25
The screen will show "Zone" and then show a gravitation
value. If needed, change the gravitation value. Use
the
Entry Mode Guide
(shown in Step 7) as an aid to
change the gravitation value (
A
and
B
). Always accept
the value by pressing the "Zero" button,
C
.
USA –
9.803
European –
9.812
NOTE:
High altitude and other circumstances may
require a different value. Contact Cascade for
gravitational value.
26
Software versions earlier than 2.13 –
After pressing
the "Zero" button to accept the gravitational value,
continue to Step 27.
Software Versions 2.13 and later –
The display will shown "done".
• To store the calibration value into
the display's memory, while "done"
shows, press and hold the "Zero"
button for three seconds. The
display will show "Set" while storing
information in the memory.
FK0273.eps
3.2-5
Weight Calibration
(continued)
24
25
26
27
Accept value
27
The display will return to normal weighing mode,
showing the current weight on the iForks.
FK0261.eps
To Store Zero Calibration Value:
Press and
hold the
"Zero"
button
for three
seconds