5.9.4 Calculate piece weight with reference scale W2
1
2
3
4
Repeat step 1 and 2 of chapter 5.9.2.
Enter the number of pieces that will be added or
removed from the scale, e.g. 2. Confirm with ‘Enter’.
Select ‘Sample PCS weight-W2(REF)’.
Add or remove the given number of pieces from
the load. Then confirm with ‘OK’.
Automatically the weight per piece is calculated
(see in the display on the left) and the number
of pieces on the main scale W1 is shown in the
display.