10
Operation Manual RAVAS Proline Touch Basic
Rev. 6
3
Weight Display And Scale Function Keys
Electronic marking plate
Scale-No. /
w eighing range
Scale
no-mot ion
symbol
Net w eight
symbol
Division e / d
Min load
Max load
Unit
Auxiliary
display
Weight
display
Scale
function keys
Charge st at e
(bat tery operat ion)
Please note that 'key' refers to the corresponding sensor field of the currently displayed template, in the same
way 'pressing a key' is to be understood as touching the respective field of the touch panel.
Scale Function Keys
Call up Service Mode;
to access the Service Mode, touch the field of the weight display (2 sec min.)
Set Zero Key
to set the displayed scale to zero (only within zero setting range, selectable in
calibration mode).
Display Select Key
to switch the display between tare weight / gross weight / gross bargraph / data
archive.
Tare Entry Key
to enter
preset tare in the tare line, the value is applied after confirmation with the
Enter-key.
Tare Key
for alternately
taring of currently displayed weight or clearing the tare weight.
Electronic Marking Plate (only for single- and dual-range and two-interval scales)
Scale-No.
W1
.
Max Load
e.g.: Max 3000kg
Maximum load (without additive tare), selectable in calibration mode.
Min Load
e.g.: Min 20kg
Permissible minimum load.
Division e / d
e.g.: e=d=1kg
Approved division e and display graduation d (in most cases e = d).