Operation Manual RAVAS Proline Touch Basic 

Rev. 6

 

Weighing Terminal 

This manual describes the basic functions and the operation of the Proline Touch weighing terminal with the 
operator interaction in the individual steps of the operating sequence. The terminal is intended for connection 
to 12 V DC power supply (

–15%) to 30VDC (+10%).  

The weighing terminal supports power saving functions for battery operation: 

 

 

On / off for printer; 

 

Power off for display backlighting after time; 

 

Power off for terminal when not in use after time; 

 

Power off on battery low after warning. 

 

2.1 

Documentation 

Apart from this documentation, additional information is provided in the following manuals: 

 

Technical Manual 

IT6000ET

 

Calibration Manual 

ADU. 

 

 

2.2 

Safety Advice 

 

 

Read this manual carefully before you operate this instrument! Keep this manual for future 
reference! 

 

It must be installed, serviced, and operated in strict compliance with all locally applicable safety 
regulations and the rules for the prevention of accidents! 

 

When this unit is included as a component part of a system, the resulting system design must be 
reviewed by qualified personnel who are familiar with the construction and operation of all 
individual components in the system and the potential hazards involved. Failure to observe this 
precaution could result in bodily injury! 

 

All switch gear connected to the unit and/or installed close to it, such as relay and  contactors, 
must be fitted with appropriate components (RC-modules, diodes) to suppress interference. 

 

This module and its associated equipment must be installed, adjusted and maintained by 
qualified personnel only! 

 

Only permit qualified personnel to operate this instrument! 
Disconnect all power to this instrument before cleaning and servicing! 

 

Exercise utmost care when making checks tests and adjustments that can actuate movable 
parts such as feeding devices, gates, flaps, conveyors, etc. Make absolutely sure that nobody is 
within reach of movable parts. Failure to observe this precaution could result in bodily injury! 

Summary of Contents for ProLine Touch Basic

Page 1: ...uct is 100 recyclable on the basis that the parts are processed and disposed off in the right manner More information can be found on our website www ravas com Rev 20150617 Printing typographical erro...

Page 2: ...2 Operation Manual RAVAS Proline Touch Basic Rev 6...

Page 3: ...Operation Manual RAVAS Proline Touch Basic Rev 6 3...

Page 4: ...thout the prior written permission of RAVAS Europe b v RAVAS Europe b v Words which we have reason to believe constitute registered trademarks are designated as such However neither the presence nor t...

Page 5: ...eighing 17 6 1 1 Weighing 17 6 1 2 Weighing Input Of ID 18 6 1 3 Weighing Load Scale 18 6 2 Operating Mode Counting 19 6 2 1 Parts Counting 19 6 2 2 Counting Select Product 20 6 2 3 Counting Calculate...

Page 6: ...Settings iForks Settings 36 6 7 3 Data Entry Settings WLX Settings 37 6 7 4 Data Entry Settings Printer Settings 38 6 7 5 Data Entry Settings Gravity Parameter 39 7 Data Transmission And Saving To Fil...

Page 7: ...ensures full operational availability Charger When the battery packs are being charged the red LED is on After the charging time of 8 hours min has elapsed the charger is switched off and the batterie...

Page 8: ...switched off to give it time to acclimatize to the new environment 1 1 3 Maintenance The calibration of every scale must be checked at regular intervals RAVAS recommends maintenance of the weighing sy...

Page 9: ...l locally applicable safety regulations and the rules for the prevention of accidents When this unit is included as a component part of a system the resulting system design must be reviewed by qualifi...

Page 10: ...ch the field of the weight display 2 sec min Set Zero Key to set the displayed scale to zero only within zero setting range selectable in calibration mode Display Select Key to switch the display betw...

Page 11: ...liary Display switchable via Display Select Key Tare 12 9kgT Display of tare weight Gross 1000kg Display of gross weight Gross weight bargraph zero to max load Approved weight storage W M approved dat...

Page 12: ...12 Operation Manual RAVAS Proline Touch Basic Rev 6 With the 123 key the layout can be switched back to the template for numeric inputs...

Page 13: ...e entered and confirmed with the Enter key Display of net weight in the main display and of tare weight in the auxiliary display By pressing the Tare key the tare is cleared and the main display retur...

Page 14: ...peration Via Display And Keyboard 5 1 Power On Press key to switch the terminal on After switching the terminal on automatically the power up messages are displayed then the program proceeds to the te...

Page 15: ...unting Counting mode Load Unload Operating mode loading unloading Totalizing Summing mode Recipe Weighing Recipe weighing mode Gravity Determination Operating mode determination of center of load Note...

Page 16: ...switched off after power up and initialization messages Power off after time In the configuration a time in min can be entered after which the terminal is switched off after the last key stroke The te...

Page 17: ...input Settings General a ticket is printed a data string transmitted and a record stored in the internal memory Note Optionally the functions Weighing with tare database and or Weighing with ID databa...

Page 18: ...eighing Input Of ID Entry step for ID Abort entry changes are ignored Confirm entry 6 1 3 Weighing Load Scale This message appears when the weight on the scale is below the min load or if it is not di...

Page 19: ...inted a data string transmitted and a record stored in the internal memory Note In the menu Data input Settings General it is possible to enable a second scale A D at present only as reference scale 6...

Page 20: ...ord in file Show next record in file Delete Delete record from file New Create new record in file Store Store changes OK Select displayed product Choose product and confirm 6 2 3 Counting Calculate Ta...

Page 21: ...Memory Select tare weight from tare memory Select previous record in tare memory Select next record in tare memory Delete Delete record from tare memory New Create new record in tare memory Save Save...

Page 22: ...Return to previous menu Parts Change the preset number of 10 parts OK Confirm displayed number of pieces Load parts and confirm Note If no reference scale is enabled under Data input Settings General...

Page 23: ...ture station with optional tare memory 6 3 1 Loading Unloading Storage Sequence for loading and unloading to a specified target value Back Return to previous menu Press key 6 3 2 Loading Unloading Ass...

Page 24: ...ous menu Tare Select tare weight from tare memory Done Current summing sequence is terminated If applicable depending on the configuration in the menu Data input Settings General a ticket is printed a...

Page 25: ...s as a totalizing scale with optional tare memory 6 4 1 Totalizing Memory Operating sequence summing without preset target Back Return to previous menu Select key 6 4 2 Totalizing Memory Assign New Ke...

Page 26: ...ous menu Tare Select tare weight from tare memory Done Current summing sequence is terminated If applicable depending on the configuration in the menu Data input Settings General a ticket is printed a...

Page 27: ...Operating Mode Recipe Weighing 6 5 1 Recipe Weighing Operating sequence recipe weighing Back Return to main menu Select key 6 5 2 Recipe Weighing Assign New Key Entry of recipe name Back Return to ma...

Page 28: ...ual RAVAS Proline Touch Basic Rev 6 6 5 3 Recipe Weighing Filling A Component Filling of a component Back Return to main menu Parts Termination of the recipe in progress OK Confirm entries Fill compon...

Page 29: ...unit is switched on for the first time first the master file data should be entered 6 6 1 Data Entry Exit Return to main menu Products Entry of product No name and reference weight g Tare Storage Entr...

Page 30: ...ile Data for up to 99 products with their product names can be stored in the product file against a 2 digit product No Show previous record in file Show next record in file Delete Delete record from f...

Page 31: ...e weights with their pertaining designation can be stored in the tare file against a 2 digit tare No Select previous record in tare memory Select next record in tare memory Delete Delete record from t...

Page 32: ...Data Entry ID Memory Up to 99 IDs can be stored in the ID file against a 2 digit ID No Select previous entry in ID file Select next entry in ID file Delete Delete entry from ID file New Record Create...

Page 33: ...of the database can be copied onto a USB device In the other direction the database can be restored Exit Return to main menu Weighing data USB Device Copy weighing data onto USB device Database USB De...

Page 34: ...Settings General Exit Return to data entry menu General Entry of general parameters iForks Settings Entry of iForks parameters see iForks installation instructions WLX Settings Entry of WLX Parameter...

Page 35: ...Delete label Summing If summing is done clear label data Weighing w Tare database Enable disable tare weight database for operating mode Weighing Weighing w ID database Enable disable ID database for...

Page 36: ...ecipe weighing Max No of columns in Recipe Weighing Entry of the max number of column in the operating mode Recipe weighing Autostart Select operating mode that is to be started automatically after po...

Page 37: ...the WLAN module of the weighing terminal Configuration Setting of connections for the WLAN module Information The function Information provides details on status of connection available networks firm...

Page 38: ...P Address Entry of IP address when printer channel Ethernet was chosen Printer bluetooth address Enter bluetooth address of bluetooth printer when printer channel Bluetooth was chosen Line feed Enable...

Page 39: ...stant variable or fork lift Distance Cell Cell Entry of distance depth between cell front and cell rear Distance Edge Cell Entry of distance depth between load stop rear and cell front Distance Middle...

Page 40: ...transmission The weighing data can also be saved in a file to this effect the parameter Store on USB device must be enabled in the menu Data Entry Settings General Numeric fields are represented in A...

Page 41: ...or operating mode Counting Reference weight g 9 numeric and always in g Note Only for operating mode Counting Destination 24 alphanumeric Recipe No 24 alphanumeric Note Only for operating mode Recipe...

Page 42: ...4567890 Terminal No 1 Date 08 01 15 Time 14 42 Consec No 0 Gross 11 0 kg Net 10 0 kg Tare 1 0 kg ID 1000 8 2 Counting 0 1 2 3 4 5 6 7 8 1234567890123456789012345678901234567890123456789012345678901234...

Page 43: ...45678901234567890 Identification Load Terminal No 1 Date 09 01 15 Time 08 28 Countername 1 Consec No 1 Gross 15 2 kg Net 14 2 kg Tare 1 0 kg ID Subtotal 14 2kg 8 3 2 Summe 0 1 2 3 4 5 6 7 8 1234567890...

Page 44: ...8901234567890123456789012345678901234567890 10000 ID 123456 Countername 1 Consec No 1 Gross 19 8 kg Tare 1 0 kg Net 18 8 kg Date 09 01 15 Time 08 32 8 4 2 Summing 0 1 2 3 4 5 6 7 8 1234567890123456789...

Page 45: ...tick may be used as data storage device The stored data are read only and cannot be deleted or changed Call up data archive with display switching key Previous Next Scroll records Search date Enter da...

Page 46: ...ular intervals is recommended The frequency at which normal maintenance cleaning and inspection should be performed when installed in a clean office environment should be twice a year However if the u...

Page 47: ...information as possible regarding the particular trouble as this may eliminate a lengthy detailed checkout procedure If possible try first to determine the conditions under which the problem occurs T...

Page 48: ...position Set jumper to correct position repeat calibration ADM not installed No A D converter installed Check A D converter Not Available No scale selected Check parameters in Service Mode ADM Defect...

Page 49: ...ds the power up zero range 2 10 or is below the power up zero range as set in the calibration 2 10 as set in the calibration Unload scale or apply dead load Powerup Motion This message appears on powe...

Reviews: