Use and maintenance manual Aria

Pag.35 

Rev.0  22/04/2022

EN

Failed ignition 

If the system does not detect the ignition of the flame within the preset time, operation will be blocked with the “No ignition” alarm.

Before relighting the stove, check that there are pellets in the hopper, that the door and ash drawer compartment are closed, that 

there are no obstructions to the combustion air inlet system and above all that, in models without self-cleaning brazier, the brazier is 

empty, clean and correctly positioned. If the problem persists, it could be due to a technical problem (ignition plug, adjustments, etc 

...), so please contact a Ravelli CAT.

 

The accumulation of unburned pellets in the brazier after a failed ignition must be removed before proceeding with a new 

ignition.

 

The brazier could be very hot: danger of burns!

 

Never empty the brazier inside the hopper.

Setting operating temperature and power: 

Set the two values following the indications given in the chapter “Description of the display” 

OPERATING PHASES OF THE APPLIANCE

Sequence of ignition phases        

IGNITION - initial pellet loading phase;

FLAME LIGHT - flame stabilization phase and reduction of combustibl

e inside the brazier;

WORK - operation phase described in the dedicated chapter;

Modulation

During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to 

MODULATION mode in which fuel consumption is minimum.

 

📌

If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to 

the appropriate connector on the rear side of the stove; and you will have to activate the reading in “SETTINGS - ENABLE 

THERMOSTAT.” On display appears the writing TON / TOFF based on thermostat request.

 

Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we recommend you use a 

thermostat with a minimum offset of 3°C if you ntend to use the comfort clima function.

Description of menu functions 

Press the key to access the MENU page

User’s manual HANDHELD TOUCH RADIO

User’s manual HANDHELD TOUCH RADIO

Pag.24 

Pag.25 

Vers. 01 of:07.04.14

Vers. 01 of:07.04.14

5

2

1

3

6

1

Settable switch-on program

2

Settable switch-off program

3

Day of the week with active program

4

Number of "chrono" program (1-2-3-4)

5

Setting the power upon programming

6

Setting ambient temperature

4

MENU

MENU

CHRONO

ENABLE CHRONO

ENABLE CHRONO

SET CHRONO 

SET CHRONO 

SET CHRONO 

SET CHRONO

SET CHRONO 1

SET CHRONO 2

SET CHRONO 3

SET CHRONO 4

ENABLE CHRONO

ENABLE CHRONO

CHRONO

USER

MANUFACTURER 

ENGINEER

MANUFACTURER 

ENGINEER

USER

USER

USER

SCREW FEEDING

SCREW FEEDING

CHRONOTHERMOSTAT

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

AIR-PELLET SET

STOVE STATE

MENU

Flow

Flow

Flow

Flow

MANUFACTURER 

ENGINEER

USER

USER

USER

SCREW FEEDING

SCREW FEEDING

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

USING THIS METHOD, IT IS NECESSARY TO VERIFY THAT AFTER EACH AUTOMATIC SHUTDOWN  

THE GRATE IS ALWAYS VERY CLEAN TO GUARANTEE CORRECT AUTOMATIC SWITCH ON.  

AUTOMATIC SWITCH ON.   

The first setting allows the activation of the CLIMATE COMFORT function. This function is intended to ensure that the room tem 

-perature set is maintained steady upon setting the maximum period of “X” minutes (SWITCH-OFF DELA 

Y: 5 MIN) before switch-ing to ECO STOP phase. The STOVE maintains this state until the temperature drops below the set 

value (CLIMATE COMFORT  DELTA : 5℃).  

For example, with the room temperature at 21 ° C, the stove switches of f when this temperature is 

reached and restarts when  the temperature reaches 15°C (21°C - 5°C - 0,5°C tolerance).  

You can also activate the function using an external thermostat, keeping in mind that this does not include the value of the hyster 

-esis.  

We recommend you use an external thermostat with a histeresys value that can be set to maximum 3°C. 

The operation of the stove could activate the switch ON/OFF phases for several times during the day; 

this may affect the  service life of the ignition coil.  

Description of menu functions  

Press the key to access the MENU page  

The TECHNICIAN and MANUFACTURER menus are protected by password.  

Chronothermostat 

With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week  

for each day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4) 
Below are given the steps for accessing the relative menu starting from Stand-By mode.  

Press the key  “access 

menu” to access  

the  

MENU page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  

“selection”  

to quickly switch to 

CRONO-THERMOSTAT.   

By pressing the Increment key you can change each value and, at step 3, enable the days of the week; 

By pressing the Increment key you can change each value and, at step 3, enable the days of the week; 

Press “confirm” to confirm the settings and switch to the next value; 

Press the “back” button to return to the CHRONO-THERMOSTAT page.  

As per the above example, it has been set as CHRONO 1 an ignition from 08.30 to 21.30 from MONDAY to  FRIDAY at the oper

-

ating power 5 with a room temperature set at 21 ° C. Programmes 2-3-4 can be set in the same manner.   

            To exit the CHRONO-THERMOSTAT function and return to Stand-by page, press the button repeatedly.  

AIR / PELLETS setting 

Setting of the PELLET-FLOW mix enables you to immediately change the quantity of pellet loaded in the brazier and the air inflow.  

The stove is tested and inspected with DIN PLUS certified pellets. If using another type of pellets or uncertified pellets, fuel may  

need adjustment. Usually, the variation involves the FLOW  percentage to adjust the input air and, therefore, the combustion; should 

the regulation of flow be insufficient, it may be necessary  to also change the percentage of PELLET load. 
Below are given the steps for accessing the relative menu starting from Stand-By mode.  

Press the key  “access 

menu” to access  

the  

MENU page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  

“selection”  

to quickly switch to 

SET  AIR  /  PELLETS.   

As per the above example, you have set a percentage of -2 for PELLETS and +3 for the FLOW 

, an indication 

that a setting like this  is a consequence of the fact that the oxygen needed for combustion is insufficient and pellet 

size is smaller than the average size of  2 cm.  

To exit the  SET AIR - PELLET function and return to Stand-by page, press the button repeatedly.  

NOTE: The number indicated during the change of parameters refers only to a percentage value that acts on the default  

parameters set on the electronic board (exclusively in the WORK phase). These values should be changed in the event  

of poor combustion, due in many cases to the purchase of pellets differing from those used during stove testing.   

 

📌

The TECHNICIAN and PRODUCER menus are password protected. Changing parameters within these menus could 

compromise the operation and safety of the stove. In this case the warranty will be invalidated.

MENU

USER

TECHNICIAN

PRODUCER

Summary of Contents for Aria

Page 1: ...USE AND MAINTENANCE MANUAL Aria...

Page 2: ......

Page 3: ...uiksaanwijzing Beachten Sie die Warnungen und Hinweise betreffend die Installation und regelm ige Wartung in der Bedienungsanleitung Respete las advertencias y las indicaciones de instalaci n y manten...

Page 4: ...c thermostat room temperature control No Useful efficiency NCV as received with electronic room temperature control No Useful efficiency at nominal heat output th nom 91 5 with electronic room tempera...

Page 5: ...andard The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report K31932021T1 8 Declar...

Page 6: ...o Trademark Marque Ravelli Modello Model Mod le Aria L oggetto della dichiarazione di cui sopra conforme alla pertinente normativa di armonizzazione dell Unione The object of the declaration described...

Page 7: ......

Page 8: ......

Page 9: ...n do not discard it without reading it Incorrect installation maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove For further informati...

Page 10: ...uels 18 TECHNICAL CHARACTERISTICS 19 Technical diagram Aria 20 Main parts 21 Description of operation 21 Recharge the fuel 22 Doors opening 22 User training 22 Safety devices 23 SHIPPING AND INSTALLAT...

Page 11: ...ing 38 Stove phase general layout 40 MAINTENANCE 43 Safety warnings for maintenance 43 Cleaning 43 Extraordinary maintenance 45 Failure cases 47 TROUBLESHOOTING 50 The appliance does not work 50 Diffi...

Page 12: ...Maximum water temperature TW max set Maximum adjustable water temperature pWnom Max working pressure 230 V 50 Hz Alimentation Distance to combustible materials dS L Left side dC Ceiling dS R Right si...

Page 13: ...the gaskets the paint job the stainless steel or cast iron combustion grille the resistance the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the pr...

Page 14: ...any inconsistency arises it will be necessary to follow the text in the original language or contact our Technical Documentation Office Symbols used in the manual symbol definition This symbol is use...

Page 15: ...y use original spare parts Any tampering and or replacements that have not been authorised by Ravelli can pose a danger to the user s safety In the event of particularly adverse weather conditions the...

Page 16: ...contract and herein the operating manual procedures are followed routine maintenance is carried out according to the times and methods set forth extraordinary maintenance is promptly carried out when...

Page 17: ...gulation chimney provide a suitable system for the supply of combustion air air intake or intake duct for watertight appliances always perform maintenance with the appliance off and cold perform clean...

Page 18: ...Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225 2 2014 standard or certified DIN PLUS more restrictive than the A1 class or ONORM M 7135 Pellet may be light or...

Page 19: ...nsumption max W 260 Electrical power consumption reduced nominal W 30 50 Stand by electrical consumption W 3 8 smoke air inlet mm 35 smoke outlet pipe mm 80 Hopper capacity kg 17 Seasonal energy effic...

Page 20: ...Pag 20 Rev 0 22 04 2022 EN 718 621 513 223 156 35 ENTRATA ARIA 80 USCITA FUMI 373 205 45 Measurements Unit of measurement Aria Height mm 718 Width mm 621 Depth mm 513 Weight kg 127 Technical diagram A...

Page 21: ...electronic control unit that manages the start up operation and shutdown phases and also includes many other functions for control programming and safety The user can choose the operating power from 5...

Page 22: ...RM button you can read the detail of the warning doors and ash pan open If the combustion chamber door the pellet hopper lid and or the ash drawer are not closed within 1 minute the stove switches off...

Page 23: ...standard equipped with a grounding circuit and all the safety systems required by the standards It should be noted that the stove s operating program has been designed to stop stove operation in the e...

Page 24: ...d that the safety distances from flammable materials are observed Verification of system compatibility has a priority over any other assembly or installation operation Local administrative regulations...

Page 25: ...anufacturer Do not connect the appliance to a collective chimney The chimney must be built applying the following regulations it must observe product standard EN 1856 1 it must be made of materials th...

Page 26: ...the presence of other combustion appliances or VMC system it is necessary to check the appliance for correct operation The appliance must be placed inside living quarters It must never be installed o...

Page 27: ...another one installed so that the outside section can be inspected It is prohibited to install two 90 bend since the ashes would quickly obstruct smoke passage causing draught problems in the applianc...

Page 28: ...ickly obstruct smoke passage causing draught problems in the appliance See Fig 2 INTERNAL CHIMNEY Fig 5 Protection from rain Covering sheet Air tight steel sheet metal T fitting with collection chambe...

Page 29: ...connected after the installation and assembly has been completed of the appliance and must remain accessible after installation To make the electrical connection proceed as described below First conn...

Page 30: ...ND Safety devices T1 Pressure switch T2 Resettable thermal breaker T3 Pellet tank contact Motors M1 Infeed screw gear motor M2 Automatic cleaning system M3 Fume exhaust system M4 Room fan Resistance R...

Page 31: ...ble in the menu Select the desired language with the scroll buttons and confirm your selection with the confirmation button In order to operate correctly the remote control should be interfaced with t...

Page 32: ...of the battery on the back of the remote control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the remote control and observe the poles Install the...

Page 33: ...N ADJUST LANGUAGE SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE The display is subdivided into three parts 1 It shows the current room temperature measured by the handheld set Moreover if...

Page 34: ...COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT THEREFORE NOT POWERED MORE...

Page 35: ...ct therefore not powered moreover we recommend you use a thermostat with a minimum offset of 3 C if you ntend to use the comfort clima function Description of menu functions Press the key to access th...

Page 36: ...ure If the type of system designed requires controlling the 3 way valve diagram 1 and 3 it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer CHRONO CHRONO EN...

Page 37: ...RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3 C IF YOU INTEND TO USE THE COMFORT CLIMA FUNCTION Operating phases of the appliance Modulation During the work phase the appliance should rea...

Page 38: ...FW VERSION LANGUAGE LANGUAGE LANGUAGE LANGUAGE ADJUST ADJUST ADJUST ADJUST In Home mode instead of room temperature measured and settable appears the line T ON if the room in which the thermostat is i...

Page 39: ...l confirm of data and switch to the page within SETTINGS menu The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window and the room...

Page 40: ...set is reached see the dedicated section WAITING START RESTART Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically IGNITION RESTART The HOT...

Page 41: ...or is connected incorrectly Contact the Support Service No power to fume extractor Contact the Support Service The fume extractor is blocked Contact the Support Service AL 05 NO IGNITION The pellet ta...

Page 42: ...obstruction or voltage drop Check the mains voltage AL 14 AUGER PHASE No cable connection to power the gear motor Check the mains voltage AL 15 AUGER TRIAC An internal part of the electronic board tha...

Page 43: ...e stove operating mode and combustion control can affect maintenance activity frequency Cleaning Perform the cleaning operations so as to guarantee correct stove operation The table below lists the ne...

Page 44: ...cold stove clean the glass with a cloth and glass cleaner Note there are stove glass cleaning products available on the market Combustion chamber cleaning To clean the ash drawer proceed as follows s...

Page 45: ...ng with their replacement Replace a worn component before it is completely broken to prevent any damage caused by sudden component breakage PARTS FREQUENCY 1 SEASON Deep combustion chamber cleaning Do...

Page 46: ...operation must be carried out by a Ravelli Assistance Centre Schedule this type of cleaning with the Ravelli Assistance Centre The stove is equipped with some hatches for cleaning the internal smoke d...

Page 47: ...eplace the electronic board contact the Technical Assistance Service AL 15 The flame does not ignite Check that the igniter warms up Check and if necessary replace the igniter AL 05 Air inlet duct blo...

Page 48: ...sed perfectly or the gasket are worn Close the door and have the gaskets replaced with original ones AL 05 AL 06 The stove stops automatically Alarm presence Check the alarm table Any alarm Active chr...

Page 49: ...ot work Remote control battery low Replace battery or connection to the stove via cable Faulty remote control Replace remote control The stove always works at maximum power Temperature not set correct...

Page 50: ...s at the inlet and outlet for prolonged downtime DISPOSAL AT END OF SERVICE LIFE Warnings for the correct disposal of the product Demolition and disposal of the appliance is under the exclusive liabil...

Page 51: ...lays Sensors Spark plugs Electronic boards Batteries Dispose of separately at authorised centres in accordance with WEEE 2012 19 EU and its national transposition E METAL STRUCTURE Dispose of separate...

Page 52: ...r s parer cet appareil et ou les piles ou les accumulateurs des autres types de d chets et de le confier au service municipal de collecte On peut demander au distributeur de pr lever le d chet d appar...

Page 53: ...r at forebygge ventuelle skader for milj et eller sundheden bedes brugeren om at behandle dette udstyr og eller de medf lgende batterier eller akkumulatorerne separat fra andre affaldstyper og at leve...

Page 54: ......

Page 55: ......

Page 56: ...f free to make any variations to the features of its products without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del commercio 12...

Reviews: