Use and maintenance manual
Calliope EU
Page 64
Rev.0 05/05/20
R
emoving refractory tiles
When replacing or cleaning the combustion chamber insulation (vermiculite), first remove the deflector plate.
Gently lift the plate and remove the pins in the side plates that hold it in place. Push the front of the deflector plate upwards and turn
it carefully, making it possible to remove the plate from the combustion chamber. Then remove the 2 upper flue gas deflector plates.
Now remove the ceramic stones on each side of the cast iron grate in the lower part of the stove. The side plates and finally the back
plate can now be removed. Do this gently so as not to damage the plates.
⚠
Refractory tiles are fragile; be careful when removing them.
Note:
The operation must be carried out when the stove is cold.
Deep combustion chamber cleaning
📌
This operation must be carried out by a Ravelli Assistance Centre. Schedule this type of cleaning with the Ravelli
Assistance Centre.
Baffle plate