Settable switch-on program

2

Settable switch-off program

3

Day of the week with active program

4

Number of "chrono" program (1-2-3-4)

5

Setting the power upon programming

6

Setting ambient temperature

4

MENU

MENU

CHRONO

ENABLE CHRONO

ENABLE CHRONO

SET CHRONO 

SET CHRONO 

SET CHRONO 

SET CHRONO

SET CHRONO 1

SET CHRONO 2

SET CHRONO 3

SET CHRONO 4

ENABLE CHRONO

ENABLE CHRONO

CHRONO

USER

MANUFACTURER 

ENGINEER

MANUFACTURER 

ENGINEER

USER

USER

USER

SCREW FEEDING

SCREW FEEDING

CHRONOTHERMOSTAT

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

AIR-PELLET SET

STOVE STATE

MENU

Flow

Flow

Flow

Flow

MANUFACTURER 

ENGINEER

USER

USER

USER

SCREW FEEDING

SCREW FEEDING

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

USING THIS METHOD, IT IS NECESSARY TO VERIFY THAT AFTER EACH AUTOMATIC SHUTDOWN  

THE GRATE IS ALWAYS VERY CLEAN TO GUARANTEE CORRECT AUTOMATIC SWITCH ON.  

AUTOMATIC SWITCH ON.   

The first setting allows the activation of the CLIMATE COMFORT function. This function is intended to ensure that the room tem 

-perature set is maintained steady upon setting the maximum period of “X” minutes (SWITCH-OFF DELA 

Y: 5 MIN) before switch-ing to ECO STOP phase. The STOVE maintains this state until the temperature drops below the set 

value (CLIMATE COMFORT  DELTA : 5℃).  

For example, with the room temperature at 21 ° C, the stove switches of f when this temperature is 

reached and restarts when  the temperature reaches 15°C (21°C - 5°C - 0,5°C tolerance).  

You can also activate the function using an external thermostat, keeping in mind that this does not include the value of the hyster 

-esis.  

We recommend you use an external thermostat with a histeresys value that can be set to maximum 3°C. 

The operation of the stove could activate the switch ON/OFF phases for several times during the day; 

this may affect the  service life of the ignition coil.  

Description of menu functions  

Press the key to access the MENU page  

The TECHNICIAN and MANUFACTURER menus are protected by password.  

Chronothermostat 

With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week  

for each day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4) 
Below are given the steps for accessing the relative menu starting from Stand-By mode.  

Press the key  “access 

menu” to access  

the  

MENU page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  

“selection”  

to quickly switch to 

CRONO-THERMOSTAT.   

By pressing the Increment key you can change each value and, at step 3, enable the days of the week; 

By pressing the Increment key you can change each value and, at step 3, enable the days of the week; 

Press “confirm” to confirm the settings and switch to the next value; 

Press the “back” button to return to the CHRONO-THERMOSTAT page.  

As per the above example, it has been set as CHRONO 1 an ignition from 08.30 to 21.30 from MONDAY to  FRIDAY at the oper-

ating power 5 with a room temperature set at 21 ° C. Programmes 2-3-4 can be set in the same manner.   

            To exit the CHRONO-THERMOSTAT function and return to Stand-by page, press the button repeatedly.  

AIR / PELLETS setting 

Setting of the PELLET-FLOW mix enables you to immediately change the quantity of pellet loaded in the brazier and the air inflow.  

The stove is tested and inspected with DIN PLUS certified pellets. If using another type of pellets or uncertified pellets, fuel may  

need adjustment. Usually, the variation involves the FLOW  percentage to adjust the input air and, therefore, the combustion; should 

the regulation of flow be insufficient, it may be necessary  to also change the percentage of PELLET load. 
Below are given the steps for accessing the relative menu starting from Stand-By mode.  

Press the key  “access 

menu” to access  

the  

MENU page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  

“selection”  

to quickly switch to 

SET  AIR  /  PELLETS.   

As per the above example, you have set a percentage of -2 for PELLETS and +3 for the FLOW 

, an indication 

that a setting like this  is a consequence of the fact that the oxygen needed for combustion is insufficient and pellet 

size is smaller than the average size of  2 cm.  

To exit the  SET AIR - PELLET function and return to Stand-by page, press the button repeatedly.  

NOTE: The number indicated during the change of parameters refers only to a percentage value that acts on the default  

parameters set on the electronic board (exclusively in the WORK phase). These values should be changed in the event  

of poor combustion, due in many cases to the purchase of pellets differing from those used during stove testing.   

Summary of Contents for Dual 7

Page 1: ...nual PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FIRE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your l...

Page 2: ...echnical programming and individualised air pressure adjustments to ensure it will operate safely and ef ciently and to avoid possible damage to the re or the home Installation of the Dual 7 Wood Pell...

Page 3: ...s 8 2 8 Safety Devices 8 2 9 Responsibilty 8 2 10 Spare Parts 8 3 What are Wood Pellets 9 4 The Components of the Stove 9 4 1 Pellet Combustion 10 5 Maintenance and Cleaning 11 5 1 Cleaning the surfac...

Page 4: ...f the Display 16 6 5 Time and Date Settings 17 6 6 Loading the Auger 18 6 7 Setting Operating Temperature and Power 19 6 8 Turning the Device on 19 6 9 Operating Phases of the Stove 20 6 9 1 Alarms 28...

Page 5: ...f fuel used IMPORTANT The above values were found during testing and may vary with the fuel type climate and installation style Testing Standard Description Class I IP 20 AS NZS 5078 2007 Appliance AS...

Page 6: ...l l a t s n I r e l a e d Solutions Fire personnel who must give the purchaser a declaration of conformity of the appliance and who will installed It is also necessary to take into consideration all t...

Page 7: ...circulation 3 Check clearances to combustibles refer page 37 2 3 Ash The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning The use of high ash fuel...

Page 8: ...ponsibility due to Poor maintenance Failure to observe the instructions in the manual Use not compliant with the safety instructions Installation that is not compliant with the regulations in force in...

Page 9: ...d and can be 1 5 twice greater than that of natural wood The diameter of the cylindrical rods is 6 10 mm and their length can vary between 10 and 50 mm Their weight is equal to about 650 kg m Due to t...

Page 10: ...d Then adjust set pellet air increasing the air percentage from 0 up to 5 If this doesn t work try increasing the loading quantity of the pellet from 0 up to 5 to reach the flame condition shown in pi...

Page 11: ...n i m i t r o f s i h t n o i t a r e g n i k r o w ho l c s t e s y r e v e e m i t e h t e v o t s s i d e n r u t n o 2 s n o i t a t o r y b t l u a f e d d n a r e t f a 8 s r u ean e h T r e 0 6...

Page 12: ...ime the stove is used and the type of pellet used To access the drawer open the door 2 figure see drawer ashes the extract and 1 figure see N B The operation must be carried out when the stove is cold...

Page 13: ...1 e smontare i laterali come in fig 2 per accedere alle botole di ispezione Le piastre sono guarnizionate pertanto prima di rimontare le botole assicurarsi che le guarnizioni che permettono l ermetici...

Page 14: ...the iron slide 2 as shown This helps to prevent the pellet bag to touch the cast iron parts Lid of pellet tank Iron slide 1 2 5 8 How to load pellet 5 9 How to remove Firex 7 Opuscolo dedicato modello...

Page 15: ...FRQWDFW ZLWK KRW VXUIDFHV Manuale utente PALMARE IDRO TOUCH RADIO Pag 22 Vers 01 del 07 04 15 Wiring RQQHFW WKH SRZHU FRUG WR WKH EDFN RI WKH VWRYH DQG WKHQ WR D ZDOO VRFNHW 7KH 2 VZLWFK LQ WKH JXUH V...

Page 16: ...VLJQDO IURP WKH KDQGKHOG VHW SUHVVLQJ WKH HQWHU NH RQ WKH KDQGKHOG VHW WKH FRPSRQHQWV VWDUW FRPPXQLFDWLQJ ZLWK HDFK RWKHU FKHFN VLJQ RQ WKH GLVSOD DFFRPSDQLHG E D VRXQG VLJQDO VKRZV WKDW WKH LQLWLDOL...

Page 17: ...andheld set Moreover if you press the DOWN scroll key you will display the temperature settings that can be changed using the two UP DOWN keys Any change made is confirmed automatically within 3 secon...

Page 18: ...e Press the key confirm to access the SETTINGS page Press the key confirm to access the USER page Press the key con firm to access the page DATE TIME Press the key selection for selection to switch to...

Page 19: ...le the rotation of the auger The appearance of the message ADJUST THE RDS SYSTEM indicates that the initial parameter testing procedure and calibration has been unsuccessfully This indication does not...

Page 20: ...hermostat optional this must be connected to the appropriate connector on the rear side of the stove and you will have to activate the reading in SETTINGS EN ABLE THERMOSTAT On display appears the wri...

Page 21: ...TA 5 For example with the room temperature at 21 C the stove switches of f when this temperature is reached and restarts when the temperature reaches 15 C 21 C 5 C 0 5 C tolerance You can also activat...

Page 22: ...nge the quantity of pellet loaded in the brazier and the air inflow The stove is tested and inspected with DIN PLUS certified pellets If using another type of pellets or uncertified pellets fuel may n...

Page 23: ...of the stove useful for service during inspection Actual flow Fume extractor revolutions Fume temperature Stove state To exit the STOVE STATE page and return to Stand by page press the button repeated...

Page 24: ...of the information shwon on the handheld set The value can vary from 0 to 100 50 with respect to Settings Firmware version Press the key confirm to access the SETTINGS page Press the key selection to...

Page 25: ...t on the stove If the AUTO function is not enabled the fan operation is not depending on stove s installed power except for the cases in which the flame switches to modulation mode and the heat exchan...

Page 26: ...e WAITING FOR FLAME The pellets ignite and take advantage of the heat in the intake air that passes through the incandescent heater tube FLAME PRESENT The flame is visible in the grate AREAS The stove...

Page 27: ...quest from ECO STOP mode coincides with an automatic switch off condition from the TIMER the stove turns on ensuring total cleaning of the brazier before switching to FINAL CLEANING INFEED SCREW OVERF...

Page 28: ...setting from SET AIR PEL LETS If the problem persists contact the Support Service Support AL 07 RESET THERMAL BREAKER PELLET DOOR OR GATE OPEN The manual reset thermostat has tripped connected to the...

Page 29: ...efore switching on the stove it is necessary to check that the brazier is clean and so that they are always excellent combustion thus avoiding any overheating that may cause changes in the color of th...

Page 30: ...30 38 4 Maintenance Record DATE WORK CARRIED OUT SIGNATURE 40 7 Maitenace record...

Page 31: ...al service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product Check with your dealer in advance for any costs to you...

Page 32: ...let Solution e r i F s approved venting components hearth components or other accessories used in conjunction with the appliance Any part of a pre existing replace system Pellet Ravelli i t u l o S on...

Page 33: ...wood pellet re purchase and attach the receipt and any other documents business cards from the retailer that sold you the re Name of Store where Pellet re was purchased Date of Purchase Amount Paid Pa...

Page 34: ...ioning the stove 38 2 6 Location of a power source 38 2 7 Internal Standard Flue Kit 50SBD N 39 2 8 External Standard Flue Kit 51ita 40 2 9 Seismic Restraint 41 2 10 Fixing to Timber Floor Framing 41...

Page 35: ...ter of smoke exhaust duct mm 80 Min max 1040 502 561 power calorofic kW 3 3 6 7 Min max hourly consump tion of pellets Kg h 86 0 95 1 5 Electrical power absorbed during operation W 240 Supply V Hz 220...

Page 36: ...down completely meaning the likelihood of any hot embers or burning fuel escaping from the combustion chamber is extremely minimal Therefore a 150mm forward projecting floor protector will be suffici...

Page 37: ...H A E External Flue J J F B I F E 7 Dual Pellet Fire Clearance to Combustibles B C A E D G F B F G E Internal Flue Location Dimension mm A B 150 C D E 100 F 0 1 0 G H I J 250 50 n a 50 0 1 0 50 25 Fr...

Page 38: ...pellet fire door 7 Dual has been Safety Tested to AS NZS 2001 2918 using the Davins manufactured flue Test Report ARS 05 1185 Installation is not exclusive to these nominated kits though alternative...

Page 39: ...6m The visible flue is finished in black and the ceiling plate is white The support angles for securing the liner to the ceiling are not shown Kit is supplied in a carton Heat resistant floor protect...

Page 40: ...and penetrating the soffit The overall height of the flue is 3 6m All visible flue has a galvanised finish and can be powdercoated on request Kit is supplied in a carton Note The Davin 51 External St...

Page 41: ...5 shall be provided 9 2 Installation 7 Dual should be installed in a centrally located position within the home This will assist the appliance to perform to the level required Dual As heats space by c...

Page 42: ...42 1 2 x 4 2 12 How to mount the side panels 10 Opuscule d di au mod le Dual 7 Brochure for Dual 7 model Brosch re f r Modell Dual 7 2 3 x 4...

Page 43: ..._________________ Phone ________________________________ Model __________________________ Serial Number ____________________ Date of Purchase __________ dd mm yy Date of Installation _________ dd mm y...

Page 44: ...44 38 4 Maintenance Record DATE WORK CARRIED OUT SIGNATURE 40...

Page 45: ...peration of my Pellet Fire I understand that warranty conditions require an authorised Pellet Fire Solutions Installer to complete the installation Signed Date Installation Details Pellet Fire Model S...

Reviews: