Brochure for models with FLASH motherboard
( firmware version ECT2008air - & ECT2008box - )
PAGE
20
4.9 smoke fan fault alarm
if the exhaust blower is faulty or the encoder does not read the number of revs, even just because the reading cable is discon-
nect or broken.
4.10 exhaust blower anomaly alarm
if the exhaust blower works at a speed 15% below the set speed.
4.11 auger blockage alarm
if a gear motor fitted with an encoder is used and parameter pr48 has been set, blockage of the auger is recorded and causes
the corresponding alarm message.
aLaRM
COnDitiOn
inVOLVeD paRaMeteRs
sMOKe sensOR aLaRM
pR35
sMOKe OVeR teMp aLaRM
sMOKe teMp.>269°C/516 F
pR35
nO ignitiOn aLaRM
if sMOKe teMp.<pR33 after tiMeR
pR01
pR01 / pR33/ pR35
anOMaLOUs FLaMe aLaRM
if sMOKe teMp. in ti < ti-1 with rea-
ding error margin
pR02 / pR35
peLLets FinisheD aLaRM
sMOKe teMp.<pR12
pR12
BLaCK - OUt
Black out time >=pR38
pR38
DepRessiOn aLaRM
Vacuum stat tripped
pR35
theRMaL saFetY aLaRM
temperature recorded at thermal
>90°C/194 F
pR35
sUCtiOn FaULt aLaRM
encoder=0000
pR35
eXtRaCtOR ReVs FaULt
15% reduction in involved parame-
ters
pR16-22 / pR29 / pR35
sCReW BLOCKage aLaRM
Ratio-motor encoder=0000
pR35 / pR48*
iMpORtant!!! each alarm is displayed on the screen only after the parameter set in the pr 35 timer alarms delay, except for the
“nO peLLet “ and “BLaCK-OUt” alarms
iMpORtant!!! For each recorded alarm code, the stove enters the “FinaL CLean” status automatically (see point “f“ of the
paragraph “1.2.1 sWitCh-OFF phase“)
iMpORtant!!! When an alarm is tripped, it is no longer possible to start the stove until this alarm has been reset by pressing
key p3.