User and maintenance manual for stoves with RDS technology
Pag.21
01/02/2016
.
7.1. Display with mode “MAIN SCREEN”
Key “1”: access key to “set room temperature” and regulation
Key “2”: access key to “set power” and regulation
Key “OK”: short press of the key to confirm and come back to the main screen; press the key 3 seconds long to switch ON and
switch OFF the stove.
The functionalities of this display when used in mode “MAIN SCREEN” are:
-Switch on and switch off of the stove
-Set of the room temperature and selection of the type of sensor (supplied sensor connected to the motherboard or sensor integrated to the
display)
-Set of the working power (1,2,3,4,5)
A- MODE WITH SUPPLIED ROOM SENSOR (DEFAULT AND SUGGESTED USE)
If you use the supplied room sensor , the display will show the room temperature.
To set and modify the room temperature press key number 1 to enter in the dedicated menu and set the desired value with key 1 and 2.
The functioning of the stove with room thermostat activated can be of 3 types:
A-With supplied room sensor positioned on the backside of the stove ( not available for insert models)
B-With room sensor integrated to the display
C-With external thermostat (not supplied)
7.1.2. Set of the room temperature
7.1.1. switch “on” and switch “off” of the stove
Before starting the stove please follow following procedure :
1-
Check that the installation is connected to the chimney
2-
Connect the power cable
3-
Set the switch on the backside of the stove on position 1
4-
Load the pellet hopper with 6 mm pellets
5-
Load the screw as described in paragraph 8.6
6-
Press key OK for 3 seconds long.
At this stage the stove will begin the ignition phase.
On the display will appear following writings:
-IGNITION (waiting time is different depending on default settings)
-WAITING FLAME (waiting time is different depending on default settings)
-FLAME LIGHT (waiting time is different depending on default settings)
-WORK (waiting time is different depending on default settings)
Calender
Room temperature
Clock
Working power
Stove status
Pic. 1
Pic. 2
7. Description of the functioning and symbology of the display
The innovation of this particular display is the communication through low voltage conveyed waves (12 volts) between the electronic
motherboard and the display. The communication is made trough a bipolar cable (ex: the cable for the stereo speakers) and the novelty is the
possibility to install the display in the wall using the optional standard frame for electrical box 503.
MAR
MODULATION
SET TEMP. ROOM
SENSOR CONSOLLE
SET TEMP. ROOM
SENSOR CONSOLLE
SET TEMP. ROOM
SENSOR CONSOLLE