Confirm with key OK 2 times and keep deselected the box SENSOR CONSOLLE (flag, see pic.2). Once reached the set temperature the
display will show MODULATION, so the stove will reduce to minimum the pellet consumption and the power as well.
7.2. Display with mode “ADVANCED”
Key “OK”: access key to the complete menu and confirmation of the settings chosen
Key “1”: scroll key and modification of the settings
Key “2”: scroll key and modification of the settings
The stove is equipped with many functions available in each menu programming. Some of these menu are accessible for the end user , other
are protected with a password so they are accessible only by authorized technian
.
1
2
3
5
6
7
8
9
10
4
-TC1+
TERM.
N.AMB.
SMOKE
SENSOR
EXTERNAL
THERMOSTAT
ROOM
SENSOR
-TC1+
TERM.
N.AMB.
N.H2O
N.PEL.
Red
Blue
Black
Black
REMARK: if you want to use the CONFORT CLIMA is advisable an external thermostat with OFF-SET of at
least 3°C.
Once reached the set temperature of the thermostat the display will show MODULATION WORK, so the stove will reduce to minimum the
pellet consumption and the power as well. If activated the mode COMFORT CLIMA, the stove will switch on and off automatically (for details
reference paragraph 8.2.)
7.1.3. set of the working power
To modify the working power press key 2 to enter in the dedicated menu and with keys 1 and 2 to set the power you desire from 1 to 5
and confirm with key OK. Increasing the power also the pellet consumption and the speed of the fan increase as well.
NOTE- It is not possible to modify the set power during the phase of MODULATION WORK.
B-MODE WITH ROOM SENSOR INTEGRATED TO THE DISPLAY
in case you want to install the display on the wall instead of on the stove as from the factory, please reference to the functioning with
supplied room sensor (as above explicated) with just one difference: the box (flag) SENSOR CONSOLLE, if you work in this mode,
should be selected by using key 2. Then confirm with the key OK ( reference ti
o pic. 1 paragraph 7.1.2.)
C-EXTERNAL THERMOSTAT MODE
if you use an external thermostat correctly connected as shown in the electrical scheme ( reference paragraph 10), the display will not show
the room temperature but the writing T ON ( when the contact is closed) or T OFF ( when the contact is open).
REMARK: TO ENABLE THE EXTERNAL THERMOSTAT, ENTER IN THE SET TEMPERATURE USING KEY 1 AND THEN PRESS
REPEATEDLY TO REACH THE VALUE “EST” ON THE DISPLAY; CONFIRM TWO TIMES WITH THE KEY OK KEEPING DESELECTED
THE BOX (FLAG) “SENSOR CONSOLLE”.
Calender
Room temperature
Clock
Working power
Stove status
SELECT POWER
MAR
MODULATION