User and maintenance manual for stoves with RDS technology
Pag.28
01/02/2016
! IMPORTANT
BY USING THIS MODUS IT IS NECESSARY TO CHECK THAT AFTER EVERY AUTOMATIC SWITCH
OFF THE FIREPOT IS CLEANED IN ORDER TO GUARANTEE A CORRECT AUTOMATIC SWITCH
ON.
8. Description of the functions
8.1. The modulation
During the working phase the stove has to reach the set room temperature; once the set temperature is satisfied, the stove goes into
MODULATION WORK, dutring which the consumption of pellet is minimum and the room fan works at minimum power.
8.2. Comfort clima
To enter in the USER MENU press two times key OK.
To enter in the menu “COMFORT CLIMA” press 6 times key 2 and confirm with OK. To modify the settings use keys 1 and 2 and by pressing
OK you confirm the data and go on to the following one.
By last confirmation with OK you save all settings and return automatically to the screen with the icons.
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
EXAMPLE:
The value set (in this case 5) has activated the Comfort Clima
function.
FUNCTIONING:
The value sets the temperature the stove goes back ON again.
Example:
- room temperature set at 21°
- Comfort Clima value set at 2
with this setting, the stove will switch off when 21°C is reached and
will be switched back on when the room temperature is 18°C (21°C
– 2 – 0,5 = 18°C). The following strings will appear in sequence on
the display:
The modulation phase is reached, as the set room temperature has
been reached. If the temperature is maintained for about 5 minutes,
the stove will shut down.
to activate it, press button OK setting a value other than OFF and
the following strings will appear on the display
Delay
Delay
MAR
MODULATION