DECLARATION OF PERFORMANCE
Declaration of performance according to Regulation (EU) 305/2011
n. : 225CPR13.07
1.
Unique identification code of the product type:
M0001JR00, residential space heating appliance fired by wood pellets
EN 14785:2006
2.
Type, batch or serial number or any other element allowing identification of the construction product as required under Art. 11(4):
Magnus,
3.
Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer:
Residential space heating appliance fired by wood pellets
4.
Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5):
Ravelli
Aico S.p.A.
Via A. Kupfer, 31
25036 Palazzolo s/O (Bs) Italia
5.
Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2):
---
6.
System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V:
System 3, System 4
7.
In case of the declaration of performance concerning a construction product covered by a harmonised standard:
The notified laboratory IMQ (NB 0051) performed the determination of the product type on the basis of type testing under system 3 and issued
test report CS20-0058801-01
8.
Declared performances:
Harmonized technical specification:
EN 14785:2006
Essential characteristics
Performance
Fire safety
Reaction to fire
A1
Distance to combustible materials
Minimum distances (mm):
rear = 100
sides = 250
front = 1000
ceiling = 650
floor = 0
Risk of burning fuel falling out
Pass
Emission of combustion products
(at 13% of O
2
)
Nominal heat output
CO 0,002 % - 25 mg/Nm
3
NOx 125 mg/Nm
3
OGC 2 mg/Nm
3
PM 12 mg/Nm
3
Reduced heat output
CO 0,051 % - 633 mg/Nm
3
OGC 2 mg/Nm
3
Surface temperature
Pass
Electrical safety
Pass
Cleanability
Pass
Maximum operating pressure
--
Flue gas temperature at nominal heat output
165 °C
Mechanical resistance(to carry a chimney/flue)
NPD
Nominal heat output
14,4 kW
Room heating output
14,4 kW
Water heating output
--
Efficiency
Ƞ
89,4 % Nominal heat output
Ƞ
93,0 % Reduced heat output
9.
The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8. This declaration of performance
is issued under the sole responsibility of the manufacturer identified in point 4.
Signed for and on behalf of the manufacturer
Claudio Mezzalira, Operations Manager
Place
Palazzolo sull'Oglio
Date
23/02/2021
Sign _______________