DECLARATION OF PERFORMANCE
Declaration of performance according to Regulation (EU) 305/2011
n. : 261CPR13.07
1.
Unique identification code of the product type:
CP01-00-001A, residential space heating appliance fired by wood pellets
EN 14785:2006
2.
Type, batch or serial number or any other element allowing identification of the construction product as required under Art. 11(4):
Mia 90,
3.
Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer:
Residential space heating appliance fired by wood pellets
4.
Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5):
Ravelli
Aico S.p.A.
Via A. Kupfer, 31
25036 Palazzolo s/O (Bs) Italia
5.
Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2):
---
6.
System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V:
System 3, System 4
7.
In case of the declaration of performance concerning a construction product covered by a harmonised standard:
The notified laboratory TÜV Rheinland Energy GmbH (NB 2456) performed the determination of the product type on the basis of type testing
under system 3 and issued test report K19032021E4
8.
Declared performances:
Harmonized technical specification:
EN 14785:2006
Essential characteristics
Performance
Fire safety
Reaction to fire
A1
Distance to combustible materials
Minimum distances (mm):
rear = 100
sides = 150
front = 1000
ceiling = 800
floor = 0
Risk of burning fuel falling out
Pass
Emission of combustion products
(at 13% of O
2
)
Nominal heat output
CO 0,004 % - 55 mg/Nm
3
NOx 149 mg/Nm
3
OGC 5,3 mg/Nm
3
PM 11 mg/Nm
3
Reduced heat output
CO 0,011 % - 134 mg/Nm
3
OGC 2 mg/Nm
3
Surface temperature
Pass
Electrical safety
Pass
Cleanability
Pass
Maximum operating pressure
--
Flue gas temperature at nominal heat output
218 °C
Mechanical resistance(to carry a chimney/flue)
NPD
Nominal heat output
9,3 kW
Room heating output
9,3 kW
Water heating output
--
Efficiency
Ƞ
87,0 % Nominal heat output
Ƞ
91,8 % Reduced heat output
9.
The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8. This declaration of performance
is issued under the sole responsibility of the manufacturer identified in point 4.
Signed for and on behalf of the manufacturer
Claudio Mezzalira, Operations Manager
Place
Palazzolo sull'Oglio
Date
19/02/2021
Sign _______________
Summary of Contents for MIA 90
Page 2: ...MANUALE D USO E MANUTENZIONE Mia 90 ...
Page 3: ......
Page 58: ...DATA INTERVENTO EFFETTUATO MANUTENZIONE ...
Page 59: ...DATA INTERVENTO EFFETTUATO MANUTENZIONE ...
Page 60: ......
Page 62: ...MANUEL D UTILISATION ET D ENTRETIEN Mia 90 ...
Page 63: ......
Page 117: ...DATE INTERVENTION ÉFFECTUÉE ENTRETIEN ...
Page 118: ...DATE INTERVENTION ÉFFECTUÉE ENTRETIEN ...
Page 119: ......
Page 120: ......
Page 122: ...USE AND MAINTENANCE MANUAL Magnus ...
Page 123: ......
Page 177: ...DATE INTERVENTION CARRIED OUT Maintenance ...
Page 178: ...DATE INTERVENTION CARRIED OUT Maintenance ...
Page 179: ......
Page 180: ......
Page 182: ...MANUAL DE USO Y MANTENIMIENTO Mia 90 ...
Page 183: ......
Page 237: ...FECHA INTERVENCIÓN REALIZADA MANTENIMIENTO ...
Page 238: ...FECHA INTERVENCIÓN REALIZADA MANTENIMIENTO ...
Page 239: ......
Page 240: ......
Page 242: ...HANDLEIDING VOOR GEBRUIK EN ONDERHOUD Mia 90 ...
Page 243: ......
Page 297: ...DATUM INTERVENTIE UITGEVOERD ONDERHOUD ...
Page 298: ...DATUM INTERVENTIE UITGEVOERD ONDERHOUD ...
Page 299: ......
Page 300: ......