20
Manuale utente PALMARE IDRO TOUCH RADIO
Manuale utente PALMARE IDRO TOUCH RADIO
Pag.28
Pag.29
Vers. 01 del 07/04/15
Vers. 01 del 07/04/15
The first setting allows you to enable the COMFORT CLIMA function which is aimed at checking that the temperature set for room/
water is maintained at the set value for a maximum period of X minutes (SHUTDOWN DELAY: 5 MIN) before switching to before
switching to ECO STOP phase. The stove remains in this state until the room or water temperature drops below the set value
(CLIMATE COMFORT DELTA : 5 ° C). The COMFORT CONTROL function allows the user to program the stove to switch off when
the set values of AIR temperature rather than WATER temperature are reached (set by the user).
For example, with the room temperature at 21 ° C, the stove switches off when this temperature is reached and restarts when the
temperature reaches 15°C (21°C - 5°C - 0.5°C tolerance).
For example, with the room temperature at 65°C, the stove switches off when this temperature is reached and restarts when the
temperature reaches 59℃ (21°C - 5°C - 0.5°C tolerance).
You can also activate the function using an external thermostat, keeping in mind that this does not include the value of the hysteresis.
We recommend you use an external thermostat with a histeresys value that can be set to maximum 3°C.
Stove’s operation may enable the switch on/off phase for several times during the day; this may compromise the shelf life
of the ignition resistance.
A DIFFERENZA DEI MODELLI CHE DISPONGONO DI PULITORE AUTOMATICO, UTILIZZANDO QUESTA
MODALITA’ E’ NECESSARIO VERIFICARE CHE DOPO OGNI SPEGNIMENTO AUTOMATICO IL BRACIERE
RIMANGA SEMPRE BEN PULITO IN MODO DI GARANTIRE UNA CORRETTA ACCENSIONE AUTOMATICA.
Description of menu functions
Press the key to access the MENU page
The TECHNICIAN and MANUFACTURER menus are protected by password.
With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week for each
day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4).Below are given the steps for accessing the relative menu
starting from Stand-By mode.
Chronothermostat
Press the key
“access menu” to
access the
MENU page
Press the key
“confirm”
to access the
USER page
Press the key
several times
to quickly switch to
CRONO-THERMOSTAT.
By pressing the Increment key you can change each value and, at step 3, enable the days of the week;
By pressing the Increment key you can change each value and, at step 3, enable the days of the week;
Press “confirm” to confirm the settings and switch to the next value;
Press the “back” button to return to the CHRONO-THERMOSTAT page.
As per the above example, it has been set as CHRONO 1 an ignition from 08.30 to 21.30 from MONDAY to FRIDAY with room
temperature set to 21°C and hot water temperature set to 51°C.
Follow the same steps to set the programs 2-3-4.
To exit the CHRONO-THERMOSTAT function and return to Stand-by page, press the button repeatedly.
.
Setting of the PELLET-FLOW mix enables you to immediately change the quantity of pellet loaded in the brazier and the air inflow.
The stove is tested and approved with DIN PLUS certified pellets. If non-certified pellets are used you may need to regulate
combustion. Usually, the variation involves the FLOW percentage to regulate the air inflow and therefore combustion; if the flow
regulation is not sufficient, it may be required to change PELLETS feeding rate as well.
Below are given the steps for accessing the relative menu starting from Stand-By mode.
AIR / PELLETS setting
Press the key
“access menu” to
access the
MENU page
Press the key
“confirm”
to access the
USER page
Press the key
several times
to quickly switch to
SET AIR / PELLETS.
As per the above example, you have set a percentage of -2 for PELLETS and +3 for the FLOW, an indication that a setting like this
is a consequence of the fact that the oxygen needed for combustion is insufficient and pellet size is smaller than the average size of
2 cm.
To exit the SET AIR - PELLET function and return to Stand-by page, press the button repeatedly.
5
2
1
3
6
1
Orario di accensione impostabile
2
Orario di spegnimento impostabile
3
Giorno della settimana con programma attivo
4
Numero programma “crono” (1-2-3-4)
5
Settaggio della temperatura ambiente
6
Settaggio della temperatura acqua caldaia
4
NOTE: The number indicated during the change of parameters refers only to a percentage value that acts on the default
parameters set on the electronic board (exclusively in the WORK phase). These values must be changed in the event of
poor combustion, due in many cases to the purchase of pellets differing from those used during stove testing.
The STAND-BY mode is activated when the temperature of the water reaches 85℃, this function is aimed at protecting the circuit
especially when COMFORT CLIMATE function is not active on boiler H2O. If the boiler is not in this condition
, it switches to STAND-BY mode to guarantee protection of the hydraulic circuit. The boiler restarts
automatically after it cooled down, on the condition that heating is requested.
Stand-by
MENU
USER
TECHNICIAN
MENU
USER
TECHNICIAN
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
CHRONO
CHRONO
ENABLE CHRONO
ENABLE CHRONO
ENABLE CHRONO
ENABLE CHRONO
SET CHRONO 1
SET CHRONO 1
SET CHRONO 2
SET CHRONO 2
SET CHRONO 3
SET CHRONO 3
SET CHRONO 4
SET CHRONO 4
MENU
USER
TECHNICIAN
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
Pellet
Flow
Flow
Flow
Flow
Pellet
Pellet
Pellet
SET AIR-PELLET
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
MANUFACTURER’S
MANUFACTURER’S
MANUFACTURER’S
Summary of Contents for Pompeii
Page 14: ...Pull to clean exchanger tube bundle 12 5 8 How to Clean the Tubulators ...
Page 32: ...30 25 Page 16 7 Maintenance Record SIGNATURE WORK CARRIED OUT DATE ...
Page 44: ...42 1 2 x 4 2 12 How to mount the side panels ...
Page 50: ...48 38 4 Maintenance Record DATE WORK CARRIED OUT SIGNATURE 40 ...
Page 52: ......
Page 53: ......