39
Internal Standard Flue Kit Pompeii
Quantity
Description
o
N
t
r
a
P
1
Galvanised outer liner
ø100mm x 900mm long
1
2
Stainless steel inner liner
ø75mm x 900mm long
4
4sb Black Stovebright oute r liner
ø100mm x 900mm long
3
5
Inner/outer flue liner spacer
2
6c
Ceiling thimble ø107mm hole
1
7c
Ceiling decor plate
ø107mm hole – white
1
8
Rain cap 75mm
1
9
Rain Cap 100mm
1
T-adaptor/cleanout – ø75mm
– black (painted)
1
702
Support angle 950mm long
– 40mm x 40mm sides
2
This flue kit may be used in new and replacement
applications in rooms with stud height of 2.4m. The
overall height of the flue is 3.6m. The visible flue is
finished in black and the ceiling plate is white. The
support angles for securing the liner to the ceiling are
not shown. Kit is supplied in a carton.
Heat-resistant
protector
Seismic restraint
(to be
25mm minimum clearance if lined:
75mm minimum clearance if unlined
600mm from
roof
penetration
Note: The Davin 50 S/B Internal Standard Flue
Kit complies with AS/NZS 2918:2001 as per
Applied Research Test Report 05/1185, dated
15 September 2005.
All
must be installed by a
installer as per the manufacturer’s
instructions and AS/NZS2918:2001.
50S
Pom
B
e
n
o
c
y
t
i
c
o
l
e
V
6
4
1
1sb
Black Stovebright outer liner
o100mm x 900mm long
3
2
Stainless steel inner Iine r
o75mm x 900mm long
4
Each 50SBPom Internal Standard Flue Kit contains:
15sb
2.7 Internal Standard Flue Kit (50)
Summary of Contents for Pompeii
Page 14: ...Pull to clean exchanger tube bundle 12 5 8 How to Clean the Tubulators ...
Page 32: ...30 25 Page 16 7 Maintenance Record SIGNATURE WORK CARRIED OUT DATE ...
Page 44: ...42 1 2 x 4 2 12 How to mount the side panels ...
Page 50: ...48 38 4 Maintenance Record DATE WORK CARRIED OUT SIGNATURE 40 ...
Page 52: ......
Page 53: ......