Use and maintenance manual RBC 8010 - RBC 8012
Page 69
Rev.0 17.07.19
EN
Stove phase synthetical layout
PHASE
DESCRIPTION
FINAL CLEANING
The stove is in the switch off phase and the cooling phase has not been completed yet.
SWITCH ON
The heater pre-heating phase has started and the pellets start to fall into the grate.
WAITING FOR FLAME
The pellets ignite and take advantage of the heat in the intake air that passes through the
incandescent heater tube.
FLAME PRESENT
The flame is visible in the grate.
AREAS
The stove has completed the switch on phase and runs at maximum set capacity.
WORK MODULA
The room temperature set has been reached.
THE GRATE
Brazier cleaning phase is active (periodic function).
ECO STOP
With Climate Comfort active, the stove switches to automatic switch-off mode when
the room temperature set is reached (see the dedicated section).
START/RESTART WAIT
Switch-on is requested but with the stove in cooling phase; once this condition is met, it
restarts automatically.
SWITCH ON RESTART
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
HOT SMOKE
The maximum fume temperature threshold has been reached. To facilitate cooling, the
stove brings the capacity to a minimum with ventilation at power level 5, leading to a
decrease
in fume temperature.
OFF
The stove is off
WAIT FOR PELLETS
OUT OF
When the switch-on request from ECO-STOP mode coincides with an
automatic switch-off condition (from the TIMER), the stove turns on ensuring total cleaning
of the brazier before switching to FINAL CLEANING.
INFEED SCREW
OVERFLOW
CONDITION: when the pellet setting (set p5) is near the continuous load condition.
SOLUTION: Set the value back to 0.
Excessive
Load
Summary of Contents for RBC 8010
Page 2: ......
Page 183: ...DATE WORK PERFORMED MAINTENANCE...
Page 184: ...DATE WORK PERFORMED MAINTENANCE...
Page 185: ......