background image

Use and maintenance manual RC-RV 120 Touch Steel

Pag.14 

Rev.1  16/06/2021

EN

GENERAL INFORMATION 

Supply and safe-keeping 

The manual is supplied in printed format. 

Keep this manual safe, with the stove, so that the user can consult it easily. 

The manual is an integral part, for safety reasons, therefore: 

• 

it must be kept intact 

(in full). If it gets lost or ruined it is necessary to immediately ask for a new copy:

• 

it must be kept with the stove until demolition

 (including relocation, sale, rental, lease, etc....). 

The Manufacturer will not be held liable for improper use of the stove and/or damage caused by operations that are not set forth in 

the technical documentation. 

Language 

The original manual was written in Italian. 

Any translations into additional languages must be carried out based on the original instructions. 

The Manufacturer is liable for the information contained in the original instructions; the translations into different languages cannot be 

fully verified therefore if any inconsistency arises it will be necessary to follow the text in the original language or contact our Technical 

Documentation Office.

Symbols used in the manual 

symbol

definition 

📌

This symbol is used to identify particularly important information in the manual. This information also concerns the 

safety of users involved in using the stove.

This symbol is used to identify important warnings for the safety of the user and/or the stove.

SAFETY MEASURES

 

General safety warnings 

 

📌

Read this instructions manual carefully before stove installation 

and use. Failure to observe the instructions set forth herein 

can void the warranty and/or cause damage to property and/

or people.  

 

Stove installation, system verification, operation verification 

and initial calibration must be carried out exclusively by qualified 

and authorised staff. 

 

The stove needs to be connected to a single chimney that 

guarantees the draught declared by the Manufacturer and 

observes the installation regulations that apply to the installation 

site. 

 

The room where the stove is installed must have an air intake. 

 

The stove must not be used as an incinerator or differently 

from its purpose

Summary of Contents for RC 120 Touch Steel

Page 1: ...USE AND MAINTENANCE MANUAL RC 120 Touch Steel RV 120 Touch Steel...

Page 2: ......

Page 3: ...Model Mod le RV 120 Touch Steel L oggetto della dichiarazione di cui sopra conforme alla pertinente normativa di armonizzazione dell Unione The object of the declaration described above is in conform...

Page 4: ...Beachten Sie die Warnungen und Hinweise betreffend die Installation und regelm ige Wartung in der Bedienungsanleitung Respete las advertencias y las indicaciones de instalaci n y mantenimiento peri di...

Page 5: ...enimiento peri dico detalladas en los cap tulos del manual de instrucciones 10 8 RV 120 Touch Steel SCHEDA PRODOTTO PRODUCT DATASHEET FICHE DE PRODUIT PRODUCTKAART PRODUKTDATENBLATT FICHA DEL PRODUTO...

Page 6: ...andard The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report in corso di cert 8 D...

Page 7: ...andard The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report in corso di cert 8 D...

Page 8: ......

Page 9: ...do not discard it without reading it Incorrect installation maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove For further informatio...

Page 10: ...AL CHARACTERISTICS 19 Measurements 20 Technical diagram RC 120 Touch Steel 20 Technical diagram RV 120 Touch Steel 21 Main parts 22 Automatic cleaning system 23 Recharge the fuel 23 Doors opening 23 U...

Page 11: ...ions 38 Setting 41 Double ducting 43 Stove phase general layout 47 MAINTENANCE 50 Safety warnings for maintenance 50 Cleaning 50 To clean the pellet tank proceed as follows 51 Extraordinary maintenanc...

Page 12: ...Opart CO at reduced power nom Efficiency at nominal power part Efficiency at reduced power pnom Minimum draught at nominal power T Flue gas temperature at nominal power 230 V 50 Hz Alimentation Distan...

Page 13: ...oor glass the gaskets the paint job the stainless steel or cast iron combustion grille the resistance the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use...

Page 14: ...rified therefore if any inconsistency arises it will be necessary to follow the text in the original language or contact our Technical Documentation Office Symbols used in the manual symbol definition...

Page 15: ...rigade Only use original spare parts Any tampering and or replacements that have not been authorised by Ravelli can pose a danger to the user s safety In the event of particularly adverse weather cond...

Page 16: ...ared in the contract and herein the operating manual procedures are followed routine maintenance is carried out according to the times and methods set forth extraordinary maintenance is promptly carri...

Page 17: ...e stove to a regulation chimney provide a suitable system for the supply of combustion air air intake or intake duct for watertight stoves always perform maintenance with the stove off and cold perfor...

Page 18: ...ble distance Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225 2 2014 standard or certified DIN PLUS more restrictive than the A1 class or ONORM M 7135 Pellet may...

Page 19: ...ical power consumption max W 250 250 Electrical power consumption reduced nominal W 57 93 61 100 Stand by electrical consumption W 2 2 smoke air inlet mm 50 50 smoke outlet pipe mm 80 80 Hopper capaci...

Page 20: ...ement RC 120 Touch Steel RV 120 Touch Steel Height mm 1145 1145 Width mm 597 597 Depth mm 599 599 Weight kg 190 190 Technical diagram RC 120 Touch Steel 535 1165 576 280 85 145 239 217 387 306 5 85 50...

Page 21: ...Use and maintenance manual RC RV 120 Touch Steel Pag 21 Rev 1 16 06 2021 EN Technical diagram RV 120 Touch Steel 1165 535 569 50 ENTRATA ARIA 386 250 217 239 80 USCITA FUMI AIR INLET SMOKE OUTLET...

Page 22: ...d by an electronic control unit that manages the start up operation and shutdown phases and also includes many other functions for control programming and safety The user can choose the operating powe...

Page 23: ...ion chamber door the pellet hopper lid and the ash drawer can only be opened when the stove is in the OFF state If one of them is not closed the pellet supply is interrupted the control unit emits an...

Page 24: ...of the house is up to standard equipped with a grounding circuit and all the safety systems required by the standards It should be noted that the stove s operating program has been designed to stop st...

Page 25: ...compatibility has a priority over any other assembly or installation operation Local administrative regulations and particular requirements of the authorities pertaining to the installation of combust...

Page 26: ...ing the following regulations it must observe product standard EN 1856 1 it must be made of materials that are suitable to guarantee resistance against normal mechanical chemical and thermal stress an...

Page 27: ...ation in the presence of other combustion appliances or VMC system it is necessary to check the appliance for correct operation The stove must be placed inside living quarters It must never be install...

Page 28: ...installed externally there is another one installed so that the outside section can be inspected It is prohibited to install two 90 bend since the ashes would quickly obstruct smoke passage causing dr...

Page 29: ...itial segment since the ashes would quickly obstruct smoke passage causing draught problems in the stove See Fig 2 INTERNAL CHIMNEY Fig 5 Protection from rain Covering sheet Air tight steel sheet meta...

Page 30: ...the stove s power cable must only be connected after the installation and assembly has been completed of the appliance and must remain accessible after installation To make the electrical connection p...

Page 31: ...rials these materials must be protected by using insulating materials or taking appropriate measures It is recommended to insulate the entire length of the ducting pipe to avoid heat dispersion It is...

Page 32: ...presente S3 Termostato esterno S4 Sonda ambiente opt Generico G1 Debimetro solo stufe con tecnologia RDS G2 Encoder lettura giri estrattore G3 Palmare RADIO Touch G4 Conta colpi pulitore automatico s...

Page 33: ...ensione GAS Segnalazione allarme uscita domotica TRF 39 M2 M3 R1 S3 G1 G3 nero rosso bianco RETE ALIMENTAZIONE 220 V S4 G4 G5 G2 Scheda OPZIONALE per gestione domotica N COM NC NO G6 G2 NC G6 NO G6 C...

Page 34: ...le in the menu Select the desired language with the scroll buttons and confirm your selection with the confirmation button In order to operate correctly the handheld set should be interfaced with the...

Page 35: ...of the battery on the back of the remote control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the handheld set and observe the poles Install the ba...

Page 36: ...RSION ADJUST LANGUAGE SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE The display is subdivided into three parts 1 It shows the current room temperature measured by the handheld set Moreover...

Page 37: ...RT CLIMA DELTA COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT THEREFORE NO...

Page 38: ...ry contact therefore not powered moreover we recommend you use a thermostat with a minimum offset of 3 C if you ntend to use the comfort clima function Description of menu functions Press the key to a...

Page 39: ...temperature If the type of system designed requires controlling the 3 way valve diagram 1 and 3 it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer CHRONO...

Page 40: ...OVER WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3 C IF YOU INTEND TO USE THE COMFORT CLIMA FUNCTION Operating phases of the appliance Modulation During the work phase the appliance sh...

Page 41: ...VERSION FW VERSION LANGUAGE LANGUAGE LANGUAGE LANGUAGE ADJUST ADJUST ADJUST ADJUST In Home mode instead of room temperature measured and settable appears the line T ON if the room in which the thermos...

Page 42: ...ll confirm of data and switch to the page within SETTINGS menu The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window and the roo...

Page 43: ...or AUTO selection screen Ventilation manual mode When manual management is active the power of the ducting can be changed Press the Access to menu key to access the MENU screen Press the confirm key...

Page 44: ...40 15 Temperature automatic mode When automatic management is active the power of the stove and the speed of the fans are automatically managed so that the desi red temperatures are reached and maint...

Page 45: ...esired temperature in the room rooms heated by the ducting the data is saved without further confirmation To go back to the CANALIZED menu press the back key Use the confirm button to go to the enable...

Page 46: ...onsidered in manual mode 3 Left ducting temperature set not considered in manual mode 4 Temperature read by the probe placed in the rooms heated by the right ducting 5 Distribution of the ducting A Au...

Page 47: ...perature set is reached see the dedicated section WAITING START RESTART Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically IGNITION RESTART...

Page 48: ...working or is connected incorrectly Contact the Support Service No power to fume extractor Contact the Support Service The fume extractor is blocked Contact the Support Service AL 05 NO IGNITION The p...

Page 49: ...e to fan obstruction or voltage drop Check the mains voltage AL 14 AUGER PHASE No cable connection to power the gear motor Check the mains voltage AL 15 AUGER TRIAC An internal part of the electronic...

Page 50: ...ts are cold Make sure that the ashes are completely cold Always operate with equipment that is appropriate for maintenance When maintenance is finished re install all of the dis assembled parts before...

Page 51: ...nished cleaning the exchanger push the scraper into the grille never leave it removed Combustion chamber cleaning To clean the ash drawer proceed as follows step action 1 The stove requires a simple y...

Page 52: ...omponent breakage PARTS FREQUENCY 1 SEASON Deep combustion chamber cleaning Door gasket Chimney Smoke conduit Schedule the above extraordinary maintenance activities with the Authorised Assistance Cen...

Page 53: ...is operation must be carried out by a Ravelli Assistance Centre Schedule this type of cleaning with the Ravelli Assistance Centre The stove is equipped with some hatches for cleaning the internal smok...

Page 54: ...Use and maintenance manual RC RV 120 Touch Steel Pag 54 Rev 1 16 06 2021 EN Inspection hatch Gasket Gasket Inspection hatch 3 Inspection hatch Gasket...

Page 55: ...in the room is clear of any obstructions and that there are no other combustion appliances or extraction hoods that create a vacuum in the room Difficult lighting closely follow the directions in the...

Page 56: ...r s parer cet appareil et ou les piles ou les accumulateurs des autres types de d chets et de le confier au service municipal de collecte On peut demander au distributeur de pr lever le d chet d appar...

Page 57: ...r at forebygge ventuelle skader for milj et eller sundheden bedes brugeren om at behandle dette udstyr og eller de medf lgende batterier eller akkumulatorerne separat fra andre affaldstyper og at leve...

Page 58: ......

Page 59: ......

Page 60: ...free to make any variations to the features of its products without notice Aico S p A Headquarter Via Consorzio Agrario 3 D 25032 Chiari BS Italy Research and Development Centre Viale del commercio 1...

Reviews: