Use and maintenance manual
Vela 11
Page 69
Rev.1 09.02.18
EN
START/RESTART WAIT
Switch-on is requested but with the stove in cooling phase; once this condition is
met, it restarts automatically.
SWITCH ON RESTART
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
HOT SMOKE
The maximum fume temperature threshold has been reached. To facilitate cooling,
the stove brings the capacity to a minimum with ventilation at power level 5, leading
to a decrease in fume temperature.
OFF
The stove is off
WAIT FOR PELLETS
OUT OF
When the switch-on request from ECO-STOP mode coincides with an automatic
switch-off condition (from the TIMER), the stove turns on ensuring total cleaning of
the brazier before switching to FINAL CLEANING.
INFEED SCREW
OVERFLOW
CONDITION: when the pellet setting (set p5) is near the continuous load
condition.
SOLUTION: Set the value back to 0.
GENERIC ALARM
The stove is in alarm state; refer to the troubleshooting chapter.
ANOMALY (general)
The stove has detected an anomaly; refer to the troubleshooting chapter.
AUTOMATIC CLEANING
SYSTEM ACTIVE
For models with automatic cleaning system it indicates the operating state of the
same.
Warning Pop -Up
ANOMALY
DESCRIPTION
SERVICE REQUEST
The threshold value of set work hours has been reached. The symbol displayed
remains active throughout the work phase. Non-routine maintenance is required
on the stove.
Alarms (table with reference codes)
TITLE
REASON
SOLUTION
AL 01
BLACK OUT
No voltage during work phase
Press the switch off key and switch on the stove
again
If the problem persists, contact the Support Service
AL 02
K PROBE
FAILURE
The K probe is malfunctioning
Contact the Support Service
The K probe is disconnected from the
electronicboard
Contact the Support Service
AL 03
OVERTEMP. K
Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
inside the stove
Switch off the stove, clean the brazier and the tube
bundle and adjust the combustion setting the Pellet/
Air values
Contact the Support Service
If the problem persists, contact the Support Service
Summary of Contents for VELA 11
Page 2: ......
Page 42: ...DATA INTERVENTO EFFETTUATO MANUTENZIONE ...
Page 76: ...DATE WORK PERFORMED MAINTENANCE ...
Page 110: ...DATE INTERVENTION EFFECTUÉE ENTRETIEN ...
Page 181: ...DATE WORK PERFORMED MAINTENANCE ...
Page 182: ...DATE WORK PERFORMED MAINTENANCE ...
Page 183: ......