016-0236-001 Rev. C
17
HYDRAULIC SYSTEM INSTALLATION
FIGURE 10. Pressure Hoses with Tee Fitting Installed on Machine Hydraulic Valve
5. Install a -8 ORFS M/M/F swivel run tee fitting (P/N 333-0012-028) in the machine’s pressure port.
6. Attach the machine’s pressure hose to the opposite end of the installed tee fitting.
7. Connect the straight end of the supplied hydraulic hose (P/N 214-1000-311) to the 90° end of the installed tee
fitting.
8. Connect the 90° end of the installed hydraulic hose to Port P on the AutoBoom valve.
FIGURE 11. Pressure and Tank Hoses Installed
9. Disconnect the machine’s tank hose from the machine’s hydraulic valve.
10. Install a -8 ORFS M/M/F swivel run tee fitting (P/N 333-0012-028) in the machine’s tank port.
11. Attach the machine’s tank hose to the opposite end of the installed tee fitting.
12. Connect the straight end of the supplied hydraulic hose (P/N 214-1000-311) to the 90° end of the installed tee
fitting.
13. Connect the 90° end of the installed hydraulic hose to Port T on the AutoBoom valve.
Swivel Run
Tee
To
AutoBoom
Valve
To
AutoBoom
Valve
Machine’s
Existing
Hoses
P
T