016-0236-001 Rev. C
15
HYDRAULIC SYSTEM INSTALLATION
MOUNT THE AUTOBOOM XRT VALVE
1. Secure the AutoBoom XRT valve (P/N 334-0235-001) to the mounting bracket (P/N 107-0235-011) using four
5/16” hex bolts and four 5/16” lock washers.
FIGURE 7. XRT Valve Mounting Location
NOTE:
Mount the AutoBoom valve so that Port P is facing up and LC and RC Ports are facing the center of
the machine.
FIGURE 8. AutoBoom XRT Valve Mounted on the Sprayer
2. Mount the REM node (P/N 063-0173-965) to the valve mounting bracket using two 1/4”-20 x 3” hex bolts, one
1/4”-20 x 2.5” hex bolt, three washers, and three 1/4” - 20 lock nuts.
NOTE:
Position the node so that the cable connectors will face down.
XRT Valve
Mounting
Location
LC
RC
P