3
Manual No. 016-0130-076 Rev. C
9
Calibration
Reset Calibration
Although it is not normally necessary, there may be circumstances under which it may be desired to reset the
AutoBoom system calibration. The AutoBoom system must be recalibrated after the system is reset. To reset
the AutoBoom system calibration:
1.
Touch the Edit icon in the Machine Configuration panel to expand the panel.
2.
Locate and select the AutoBoom button. The AutoBoom Features tab will be displayed.
3.
Touch the Calibrate tab and select the Reset Defaults icon in the lower, left corner of the tab.
4.
When prompted to accept the reset, touch ‘Yes’ to proceed.
Note:
Resetting the AutoBoom system calibration will delete all system settings and adjustments that
have been performed. Before resetting the AutoBoom calibration, refer to the Reset Defaults
section on page 21.
5.
Refer to the
to recalibrate AutoBoom before engaging the system during a field operation.
PowerGlide Plus Calibration
Important:
Read and perform the process outlined in the Pre-Calibration Hydraulic Diagnostics section on page 8
before starting the calibration process.
Boom Calibration
1.
Touch the Edit icon in the Machine Configuration panel to expand the panel.
2.
Locate and select the AutoBoom button. The AutoBoom Features tab will be displayed.
Note:
If the AutoBoom button is not displayed or displays as unavailable, refer to Chapter 5,
Troubleshooting, to diagnose and correct issues with the AutoBoom control node.
3.
On the Features tab, select the options desired for operation of the AutoBoom system. Refer to the
section on page 14 for additional information on the available features.
4.
Touch the Sensor Offsets tab to access sensor height offset settings.
5.
If ultrasonic sensors are installed, use the up and down arrows to set the vertical offset of the sensor body
from the spray nozzle for each sensor location. Refer to the
details on setting or adjusting the sensor offsets.
6.
Select the Calibrate tab to access the AutoBoom calibration.
Edit
AutoBoom
Calibrate
Edit
AutoBoom
Features
Sensor
Offsets
Tuning
Calibrate