15
1. INITIAL CONSOLE PROGRAMMING
When you first turn on Console power, after all installation procedures have been
completed, the Console will display "US" in the display window. This means you
must "calibrate" or program the Console before it can be operated. This is a one-
time operation which does not have to be repeated. Turning OFF the POWER ON/OFF
switch does not affect the Console memory. All data is retained in non-volatile
memory.
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT: If an entry selection error is made during Steps 1-4, place the power
switch to the OFF position. Depress
and hold while placing the power
switch to ON. This will "reset" the Console. The display will now show "US".
The following steps must be followed:
1)
1)
1)
1)
1) Display US (gallons) or SI (liters).
a) Depressing momentarily
steps the display from US to SI.
b) Depressing momentarily
steps the display from SI to US.
2)
2)
2)
2)
2) Selecting US or SI.
a) To select US or SI, step with until the desired code is displayed.
b) Momentarily depress
. The display will now show C-Sd.
3)
3)
3)
3)
3) Display C-Sd (Standard Valve) or C-FC (Fast Close Valve).
a) Depressing momentarily steps the display from C-Sd to C-FC.
b) Depressing momentarily
steps the display from C-FC to C-Sd.
4)
4)
4)
4)
4) Selecting C-Sd or C-FC.
a) To select C-Sd or C-FC step until desired code is displayed.
b) Momentarily depress . The display will now show CAL.
5)
5)
5)
5)
5) Enter METER CAL in key labelled:
6)
6)
6)
6)
6) Enter target LIQUID CAL application rate (GPT) [lit/MT] in key labelled:
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: A decimal point is displayed automatically. Therefore, twenty gallons per
ton is entered as 20.0, not 2.0.
7)
7)
7)
7)
7) Enter initial GRAN CAL calibration number of 200 in key labelled: