FIGURE 31. Trident Rinse Mounted
2. Remove the existing M220 cap from the existing tank tee. Reuse the clamp and gasket to secure the rinse valve
plumbing assembly to the rinse tank tee.
3. If needed, assemble the rinse tee for dual pump stations as shown below. Use pipe thread sealant on the
threaded joints.
FIGURE 32. Assembling Dual Pump Station Rinse Tee Fittings (Dual Pump Station System Only)
MIXER INSTALLATION
PLUMBING MIXER ASSEMBLY
1. Assemble the mixer inlet and outlet plumbing as shown below using the fittings, clamps, and gaskets provided.
3/4” 3-Way
Ball Valve
3/4” MNPT to 3/4”
Hose Barb Elbow
3/4” Cap
Existing Rinse Tee
on Machine
3/4” Hose Barb
to 1/2”NPT
1/2” NPT Tee
1/2” NPT to 3/4”
Hose Barb
Elbow
To Pump 1
To Pump 2
To Rinse Valve
Assembly