10
16. Using the LEFT/RIGHT and UP/DOWN arrow enter a new value for the Rate or
Desired weight.
17. When the desired value is entered press the “ok” button. The Catch Test Summary
will be displayed with the new values. If the values are satisfactory continue by
pressing the NEXT button.
NOTE:
If the Estimated Test Time is less than 10 mins, the NEXT button will not
appear. Adjust the calibration values accordingly.
FIGURE 18. Edit Catch Test Value
18. If no product has been measured though the meters, use the “PRIME” button to
prime the meters, and repeat as necessary. Make sure the container is empty
before proceeding to the next step.
FIGURE 19. Priming and Start Catch Test
19. Press the START button to begin metering product into the container. The Test will
begin and display how far along the catch test is and it also displays the Meter
RPM.