C
HAPTER
5
58
RoGator 64/74/86/SS Series AutoBoom Installation Manual
INSTALL THE ULTRAGLIDE SENSORS
BOOM SENSOR MOUNTING LOCATIONS
Sensor mounting locations may be influenced by the boom configuration. If an object enters the sensor’s blind
range unexpectedly, a false echo return to the sensor could occur, causing the boom to drop and result in sensor
or boom damage. To ensure optimal operation of the UltraGlide system and to protect the sprayer boom, mount
the sensors on the front side of the boom, 8 - 10” above the lowest hanging part of the boom.
FIGURE 7. Illustration of Sensor’s Blind Range
Mount the Boom Sensors
FIGURE 8. Mounted Boom Sensor
WARNING
The machine must remain stationary and
switched off, with the booms unfolded and
supported, during installation or maintenance.
Bottom of Sprayer
Boom
Sensor to Target
Distance
Sensor Blind Range (8”)
Summary of Contents for RoGator 64 Series
Page 9: ...2 Manual No 016 0230 044 Rev F 5 INTRODUCTION ...
Page 10: ...CHAPTER 2 6 RoGator 64 74 86 SS Series AutoBoom Installation Manual ...
Page 21: ...3 Manual No 016 0230 044 Rev F 17 POWERGLIDE POWERGLIDE HYDRAULIC SCHEMATIC ...
Page 48: ...CHAPTER 4 44 RoGator 64 74 86 SS Series AutoBoom Installation Manual GEN II CABLING ...
Page 61: ...5 Manual No 016 0230 044 Rev F 57 ULTRAGLIDE ULTRAGLIDE HYDRAULIC SCHEMATIC ...
Page 71: ...Manual No 016 0230 044 Rev F 67 ULTRAGLIDE ULTRAGLIDE WIRING SCHEMATIC GEN I CABLING ...
Page 72: ...CHAPTER 5 68 RoGator 64 74 86 SS Series AutoBoom Installation Manual GEN II CABLING ...
Page 75: ...6 Manual No 016 0230 044 Rev F 71 REPLACEMENT PARTS SENSORS ...
Page 76: ...CHAPTER 6 72 RoGator 64 74 86 SS Series AutoBoom Installation Manual ...