Initial Machine Calibration: Initial Machine Calibration
21
INITIAL MACHINE CALIBRATION
FIGURE 21. Right WAS Calibration Screen
6. Continue driving forward between 1 - 4 mph [2 - 6 km/h].
7. Turn the steering wheel all the way to the right steering lock.
8. Select the
Right
button to set the right WAS value.
NOTE:
Do not move the steering wheel until the Calibration Complete screen is displayed.
FIGURE 22. WAS Calibration Complete Screen
9. Review the WAS calibration details.
10. Press the
Next
arrow.
HYDRAULIC SYSTEM CALIBRATION
The steering control calibration process
allows the SC1/TC1 system to learn the hydraulic capabilities of the
machine for optimal steering performance in the field.
NOTE:
Preparation and Best Practices
section on page 10 for tips on completing the auto-steering
calibration successfully.
It is recommended to complete the SC1/TC1 Steering Control Calibration for optimal system
performance. However, the automatic calibration may be bypassed by selecting the
Use Quick