Machine Settings and Tuning: Steering Setup Tab
49
MACHINE SETTINGS AND TUNING
If the operator switch is in a non-functional state, the operator may opt to use the touch screen activity monitor.
The activity monitor uses input on the field computer touch screen to reset a 7 minute timer. If the timer does
expire, the system will disable automated steering until the operator touches the screen and reengages the
steering system.
CURRENT VOLTAGE
Displays the current switch voltage. This display may be useful to adjust the upper and lower voltage limits if
necessary.
LOWER LIMIT
Use this setting to set the lower voltage limit. This is the voltage at which the switch will toggle when the operator
is seated or the Activity Monitor is enabled.
UPPER LIMIT (DOUBLE POLE SWITCH ONLY)
Use this setting to adjust the upper voltage limit. Set the upper limit so that the current voltage reading remains
below the upper limit while the operator is seated. If the presence switch voltage exceeds the upper limit, the
presence switch will disengage steering.
STATUS
Displays the operator presence switch status. Toggle the presence switch (e.g. stand or sit in the operator seat) and
confirm that the status indicates the switch is on when the operator is seated.
If the status does not change, but the current voltage changes, adjust the upper and lower limit settings as
necessary.
NOTE:
section on page 33 for information on the status displayed in
this area.