41
APPENDIX 6
PROCEDURE TO PROGRAM SERIAL 660 FOR NEW LEADER
MARK IV INTERFACE
The initialization for the console should be:
1)
US for acres, pounds, etc.
2)
SP1 or SP2, depending on the truck's speed sensor.
3)
GR1 for single belt.
4)
C-NL1 for "Hall Effect" control valve. C-NL2 for "Reed Switch" control
valve.
5)
The rest of the console calibration is the same as described in the SCS 660
GRANULAR APPLICATION manual. (BOOM CAL, SPEED CAL, METER CAL, SPREADER
CONSTANT [starting values below], VALVE CAL, RATE 1 CAL, and RATE 2 CAL).
Spreader Constants (for New Leader/HiWay Equipment Co L-3020 box with 0.256 Chain & Belt
Over Chain, Mark IV stepper system only). Starting Spreader Constant is 1172 for the
first inch of gate opening. The Spreader Constant for a desired gate height is determined
by dividing 1172 by the exact gate opening. One inch increments are listed below for
your convenience.
2" gate = 586
3" gate = 391
4" gate = 293
5" gate = 234
6" gate = 195
7" gate = 167
8" gate = 147
9" gate = 130
10" gate = 117
Spreader Constants (for New Leader/HiWay Equipment Co L-2020 box with 0.192 Chain & Belt
Over Chain, Mark IV stepper systems only). Starting Spreader Constant is 1563 for the
first inch of gate opening. The Spreader Constant for a desired gate height is determined
by dividing 1563 by the exact gate opening. One inch increments are listed below for
your convenience.
2" gate = 782
3" gate = 521
4" gate = 391
5" gate = 313
6" gate = 261
7" gate = 223
8" gate = 195
9" gate = 174
10" gate = 156
NOTE:
Verify Spreader Constant by performing Spreader Constant calibration
procedure in Appendix 5 before field application.