C
HAPTER
3
16
SmarTrax™ Calibration & Operation Manual
1. Park the machine on a flat surface.
2. Locate and select the SmarTrax module. The calibration wizard will start automatically if the SmarTrax system
requires calibration.
3. Select
Next
.
SYSTEM DISENGAGE CALIBRATION
SMARTRAX SYSTEMS WITH A PRESSURE SWITCH OR FLOW SWITCH INSTALLED
NOTE:
This section applies only to SmarTrax systems utilizing a pressure or flow switch to disengage the
SmarTrax system when the steering wheel is turned. If a pressure transducer is installed in the
SmarTrax system, refer to “SmarTrax Systems with a Pressure Transducer Installed” on page 17 to
calibrate the SmarTrax system.
FIGURE 6. Steer Switch Test Screen
1. Verify that the steering wheel icon is green when the steering wheel is not being touched.
NOTE:
If the steering wheel icon is red, increase the disengage setting on the pressure switch to require
more steering input to disengage SmarTrax.
2. Turn the steering wheel. The following screen will appear:
FIGURE 7. Disengage Calibration Screen
3. Verify that the steering wheel icon is red when the steering wheel is being turned.
NOTE:
If the steering wheel icon is green, decrease the disengage setting on the pressure switch to require
less steering input to disengage SmarTrax.
Summary of Contents for SmarTrax
Page 12: ...CHAPTER 1 6 SmarTrax Calibration Operation Manual ...
Page 16: ...CHAPTER 2 10 SmarTrax Calibration Operation Manual ...
Page 42: ...CHAPTER 3 36 SmarTrax Calibration Operation Manual ...
Page 76: ...CHAPTER 4 70 SmarTrax Calibration Operation Manual ...
Page 138: ...CHAPTER 6 132 SmarTrax Calibration Operation Manual ...
Page 151: ...8 P N 016 0171 277 Rev L 145 SYSTEM DIAGRAMS FIGURE 4 SmarTrax with Envizio Pro and RGL 600 ...