P/N 016-0171-277 Rev. L
69
VIPER 4/4+ CALIBRATION AND OPERATION
SYSTEM SETTINGS
RESET CALIBRATION
Resetting the SmarTrax system calibration will delete all system settings and adjustments that have been
performed. Before resetting the SmarTrax calibration, write down the current system settings for reference
later. Recalibrate the SmarTrax system after the system is reset.
System Setting
Average
Setting
Suggested
Range
Function
Line Acquisition (LA)
Aggressiveness
10
4 to 16
The LA Aggressiveness value affects how
quickly the machine steers toward a displayed
guidance line when it is traveling further than
24 inches [60 cm] from the desired path.
OnLine (OL) Sensitivity
10
4 to 20
The OL Sensitivity value affects the response of
the machine while steering within 24 inches [60
cm] of the displayed guidance line.
System Setting
Average
Setting
Acceptable
Range
Function
Zero Yaw
0
-2 to 2
Indicates amount error in the internal yaw
sensor while no yaw motion is present.
Message Frequency - GGA
and VTG
10 Hz
10 Hz
Displays the frequency of GGA messages from
the GPS receiver.
Message Frequency - ZDA
.3 Hz
.3 to 10 Hz
Displays the frequency of GGA messages from
the GPS receiver.
HDOP
2.5
N/A
Indicates the quality of the GPS signal.
Edit
SmarTrax
System Information
Summary of Contents for SmarTrax
Page 12: ...CHAPTER 1 6 SmarTrax Calibration Operation Manual ...
Page 16: ...CHAPTER 2 10 SmarTrax Calibration Operation Manual ...
Page 42: ...CHAPTER 3 36 SmarTrax Calibration Operation Manual ...
Page 76: ...CHAPTER 4 70 SmarTrax Calibration Operation Manual ...
Page 138: ...CHAPTER 6 132 SmarTrax Calibration Operation Manual ...
Page 151: ...8 P N 016 0171 277 Rev L 145 SYSTEM DIAGRAMS FIGURE 4 SmarTrax with Envizio Pro and RGL 600 ...