5
P/N 016-0171-277 Rev. L
75
VIPER PRO CALIBRATION AND OPERATION
3. Select one of the
Profile
options
from the bottom of the Machine Type list.
4. Select
Next
.
5. Select
New, Load,
or
Reset
.
•
New
- Creates a new machine profile.
•
Load
- Allows the operator to select an existing profile. Load will not be displayed as an option until a
machine calibration has been performed and a new profile has been set up.
◦
If the profile chosen has previously been calibrated on the machine, the calibration process is
complete.
◦
If the profile chosen has not been calibrated on the machine, the calibration process must be
completed as outlined in the following sections in this manual.
•
Reset
- Clears the previous profile settings. Once Reset is selected, the operator must select the machine
from the Machine Type list and the calibration process must be completed as outlined in the following
sections in this manual. Reset will not be displayed as an option until a machine calibration has been
performed and a new profile has been set up.
MACHINE-SPECIFIC CONFIGURATION
NOTE:
It may be necessary to configure the GPS com port in the field computer to allow GPS
communication with the SmarTrax. Refer to the Viper Pro Installation and Operation Manual
(P/N 016-0171-122) for information on com port configuration and additional machine measurements
(such as guidance width) that must be entered into the field computer.
Before the SmarTrax system may be enabled, the SmarTrax system must be calibrated for the specific vehicle
being used. Complete the following steps to configure the machine specifications in the Viper Pro and the
SmarTrax system.
FIGURE 5. Machine Configuration Menu
1. Select the specific machine type from the Machine Type list. If the specific machine is not listed, choose the
generic machine type that best fits the machine:
•
FS Tractor - Front-steered tractor
•
SP Sprayer RBoom
- Self-propelled sprayer with a rear boom
•
Articulated
Summary of Contents for SmarTrax
Page 12: ...CHAPTER 1 6 SmarTrax Calibration Operation Manual ...
Page 16: ...CHAPTER 2 10 SmarTrax Calibration Operation Manual ...
Page 42: ...CHAPTER 3 36 SmarTrax Calibration Operation Manual ...
Page 76: ...CHAPTER 4 70 SmarTrax Calibration Operation Manual ...
Page 138: ...CHAPTER 6 132 SmarTrax Calibration Operation Manual ...
Page 151: ...8 P N 016 0171 277 Rev L 145 SYSTEM DIAGRAMS FIGURE 4 SmarTrax with Envizio Pro and RGL 600 ...