Chapter 8
132
Viper Pro Installation & Operation Manual
Self Test Speed.
The self test speed allows the field computer to control product application functions while
the vehicle remains stationary. This feature allows the operator to test or troubleshoot the CAN and product
control systems. For best results, enter a value approximately equal to normal application speeds.
Note:
A speed cal must be entered to allow the test speed feature to function.
The test speed will reset to zero if the field computer receives a pulse from the actual speed
sensor. To keep the test speed from disengaging, disconnect the speed sensor from the system.
AccuBoom Node.
Select the type of AccuBoom node connected to the CANbus. If no AccuBoom node is
installed, ensure “Combo” is selected.
Audible Alarm.
When the audible alarm setting is enabled, the Viper Pro will sound a five second alarm tone if
an alert condition or alarm setting is detected on the CANbus (i.e. low tank or bin, zero speed, off rate percent
etc.).
The following alarms conditions may be enabled and will sound a tone if the audible alarm feature is enabled:
Note:
Audible Alarms are enabled by default. Refer to the Feature Settings Area section on page 134 for
additional information about the above alarm settings.
Enable Injection Flush.
If a Raven Sidekick Pro with Rinse Assist enabled is connected to the field computer,
enable the rinse assist feature to allow the operator to engage the Rinse Assist feature via the Viper Pro
interface. Refer to the
Sidekick Pro Installation and Operation Manual
for additional information on the Rinse
Assist feature.
Boom Capacity.
Enable the boom capacity feature on the Miscellaneous Settings screen to allow the field
computer to monitor the overall volume per minute for all products being applied. To display the current boom
capacity used during a field operation:
To display the current boom capacity used during a field operation:
1.
Touch the Display Data button on the main screen.
2.
Touch within the Display Data prompt until the boom capacity information is displayed.
•
Dual Flow % (Percent)
•
Flow/Shaft Alarm
•
Off Rate % (Percent)
•
Vacuum/Bin Alarm
•
Low Tank
•
Zero Speed Shutoff
•
Low Limit
Summary of Contents for Viper Pro
Page 1: ... Software Version 3 10 Viper Pro Installation Operation Manual ...
Page 42: ...Chapter 3 32 Viper Pro Installation Operation Manual ...
Page 132: ...Chapter 6 122 Viper Pro Installation Operation Manual ...
Page 138: ...Chapter 7 128 Viper Pro Installation Operation Manual ...
Page 180: ...Manual No 016 0171 122 Rev I 170 Advanced Settings and Features ...
Page 194: ...Chapter 9 184 Viper Pro Installation Operation Manual ...
Page 214: ...Chapter 11 204 Viper Pro Installation Operation Manual ...
Page 262: ...Appendix B 252 Viper Pro Installation Operation Manual ...
Page 276: ...Appendix F 266 Viper Pro Installation Operation Manual ...
Page 284: ...Appendix I 274 Viper Pro Installation Operation Manual ...
Page 292: ...Appendix J 282 Viper Pro Installation Operation Manual ...
Page 299: ......