Appendix B
244
Viper Pro Installation & Operation Manual
Band Spraying Rate Adjustment
To calculate the adjusted applied rate for band spraying applications, use the following formula:
where BR = the Broadcast Rate, BW = the bandwidth, S = the spacing between the tips, and AR = the Adjusted
Rate for band spraying.
For Example:
If the Broadcast Rate is 20 GPA [187 L/ha], the band width is 14 inches [35 cm], and the tip spacing is 40
inches [101 cm]:
Therefore, the adjusted rate is 7 GPA [65 L/ha].
Verifying Flow Rate Limits
The target rate for an application must be within the range of that specified for the Raven flow meter installed.
Flow Meter Model
Flow Range
Average Meter
Cal Value
RFM 5
0.05 - 5 GPM [0.2 - 18.9 lit/min]
5500
RFM 15
0.3 - 15 GPM [1.1 - 56.8 lit/min]
1750
RFM 60P
1 - 60 GPM [3.8 - 210 lit/min]
720
RFM 100
3 - 100 GPM [11.4 -380 lit/min]
700
RFM 200/ 200 Poly
15 - 200 GPM [56.8 - 760 lit/min]
164
RFM 400
25 - 400 GPM [94.6 - 1515 lit/min]
80
BR
BW
×
S
-----------------------
AR
=
AR
20 187
[
]
14 35
[ ]
×
40 101
[
]
-------------------------------------------
7 65
[ ]
=
=
Summary of Contents for Viper Pro
Page 1: ... Software Version 3 10 Viper Pro Installation Operation Manual ...
Page 42: ...Chapter 3 32 Viper Pro Installation Operation Manual ...
Page 132: ...Chapter 6 122 Viper Pro Installation Operation Manual ...
Page 138: ...Chapter 7 128 Viper Pro Installation Operation Manual ...
Page 180: ...Manual No 016 0171 122 Rev I 170 Advanced Settings and Features ...
Page 194: ...Chapter 9 184 Viper Pro Installation Operation Manual ...
Page 214: ...Chapter 11 204 Viper Pro Installation Operation Manual ...
Page 262: ...Appendix B 252 Viper Pro Installation Operation Manual ...
Page 276: ...Appendix F 266 Viper Pro Installation Operation Manual ...
Page 284: ...Appendix I 274 Viper Pro Installation Operation Manual ...
Page 292: ...Appendix J 282 Viper Pro Installation Operation Manual ...
Page 299: ......