Manual No. 016-0171-122 Rev. I
251
Meter Cal
A magnetic pickup coil must be mounted near the bolt heads on the spinner to measure the spinner speed
during operation. Calculate the meter cal by multiplying the number of pulses (bolt heads) per revolution by 10.
For Example:
If the number of pulses per revolution is 4:
then the value for the meter cal would be 40.
Spreader Constant
The spreader constant should be set to 0.
Rate Cal
Set the rate cal value to the desired RPM of the spinner.
MeterCal
N
10
×
=
4
10
×
40
=