5
Manual No. 016-0171-122 Rev. I
103
Using the Viper Pro System
Creating Application Reports
When a field operation is completed, the operator may have the Viper Pro create a job report with the coverage
map and application or coverage data collected within the open job. The job report may then be transferred to
a home or office computer for viewing and archiving or printed as a visual report for a customer.
Information such as field, product(s) and weather information contained in the application report may be
entered during the job on the Viper Pro or on a home or office PC. The Viper Pro creates reports in both
shapefile and bitmap (.bmp) formats. The shapefile report will require a shapefile editing program to enter
report information while the bitmap report may be edited using a simple image editing tool such as Microsoft
®
Paint.
Note:
The job information is also provided in the .jdp (job data package) used with Slingshot web
services for creating application reports.
Refer to the following sections to enter report information in an job file before creating the job report. Report
information must be entered while the job is open or in progress and may be entered at any time while the job
is open. If a job is closed prior to entering report information, the job file must be re-opened to edit or complete
report information.
Note:
To re-open a job file and add report information, be sure to select the
Add to Job
option when
opening the job file.
An application report consists of:
•
Customer Information
•
Field Information
•
Field Conditions
•
Weather Information
•
Applicator Information
•
Vehicle Information
•
Product Information
•
Report Notes
Dual Flow
This alarm activates for an injection application system when the flow
switch monitor and the actual flow readings are out of the specified
tolerance. This alarm also activates when Gran 3 is selected as the
application type and the rates sensed by the dual encoders are out of the
specified tolerance.
Zero Speed
This alarm activates when the speed of the vehicle drops below 0.7 MPH
[1.1 km/h] and the Zero Speed Shutoff function is enabled. Cycle the
master switch to clear the alarm and resume product control.
Alarm
Condition
Summary of Contents for Viper Pro
Page 1: ... Software Version 3 10 Viper Pro Installation Operation Manual ...
Page 42: ...Chapter 3 32 Viper Pro Installation Operation Manual ...
Page 132: ...Chapter 6 122 Viper Pro Installation Operation Manual ...
Page 138: ...Chapter 7 128 Viper Pro Installation Operation Manual ...
Page 180: ...Manual No 016 0171 122 Rev I 170 Advanced Settings and Features ...
Page 194: ...Chapter 9 184 Viper Pro Installation Operation Manual ...
Page 214: ...Chapter 11 204 Viper Pro Installation Operation Manual ...
Page 262: ...Appendix B 252 Viper Pro Installation Operation Manual ...
Page 276: ...Appendix F 266 Viper Pro Installation Operation Manual ...
Page 284: ...Appendix I 274 Viper Pro Installation Operation Manual ...
Page 292: ...Appendix J 282 Viper Pro Installation Operation Manual ...
Page 299: ......