Fig. 32
Fig. 33
2 -
Elbow bend
3 -
Elbow bend
4 -
Flue extension
6 -
Straight header
7 -
Roof fl ashing
23
Cut a 105 mm diameter hole through the ceiling
and/or roof, at the point previously marked.
Fit a roof flashing sleeve (fig. 33 item 7) to the roof,
available from Ravenheat Manufacturing.
Insert the Vertical Flue terminal assembly through
the flashing plate from the outside.
Fix the appliance to the wall, locating onto the
hanging bracket.
Measure the vertical distance between the top of
the flue (Fig. 31) and the bottom of the flue terminal
assembly (Fig. 32). The measurements should be
taken from the outer diameter of the flue.
NOTE: Where this length does not match any
standard combination of the extensions, they can
be cut to the required length (Fig. 32).
When cutting both inner and outer ducts of the
extension, always cut on spigot side, and they must
be de-burred.
5.8 REASSEMBLE
BOILER
AS
PER
(sect.
5.6).
5.8.1
Fitting valve pack
Remove plastic caps from boiler connection
and fit valves as per fig. 33 using washers
provided.
5.9 GAS
CONNECTION
(fig.
33).
5.9.1
A minimum working gas pressure of 20 mbar
(8 in w.g.) must be available at the boiler inlet
at full flow rate (37 mbar for propane, 29 mbar
for butane).
5.9.2
Fit gas service cock to the boiler via the union
nut and connect gas pipe. Do not overtighten
and use another spanner as a counter force to
avoid straining internal connections.
Important consult (sect 4.5.1).
5.10
CENTRAL HEATING CONNECTION
(fig.
34).
5.10.1
Before any central heating connections are
made to the boiler all system valves should
be opened and the system thoroughly flushed
out with cold water.
- Connect the central heating return pipe
to the isolating cock.
- Connect the central heating flow pipe to
the isolating cock marked CHF.
- Pipe dimensions and positions are
marked on template supplied.
Summary of Contents for 780 Series
Page 2: ......
Page 7: ...7 Fig 3 OVERALL DIMENSION ...
Page 34: ...34 Fig 45 Fig 44 Fig 46 ...
Page 36: ...36 Fig 48 Fig 47 Fig 49 Fig 50 Fig 51 ...
Page 42: ...Fig 59 42 SECTION 9 ELECTRICAL SYSTEM DIAGRAM ...
Page 46: ...79 83 105 46 50 27 16 39 17 2 22 100 1 4 5 11 8 SECTION 11 ...
Page 49: ...49 ...
Page 50: ...COD 0017LIB06010 2 03 2010 ...