NOMINAL HEAT INPUT NET QMS
20.0 kW
MINIMUM HEAT INPUT NET
3.7 kW
NOMINAL HEAT OUTPUT
19.5 kW
NOMINAL HEAT OUTPUT CONDENSING
21.4 kW
MINIMUM HEAT OUTPUT
3.6 kW
MINIMUM HEAT OUTPUT CONDENSING
4.0 kW
GAS RATE
max
2.1 m
3
/h
AFTER 10 MINUTES
min
0.4 m
3
/h
INLET PRESSURE
20 mbar
FAN SPEED Max 4200 rpm - 140 Hz Combustion % CO
2
: 9.0 (+ 0.5 / - 0.5) Case ON
C.H. min 1300 rpm - 43 Hz 9.0 (+ 0.5 / - 0.5) Case OFF
ELECTRICAL SUPPLY
230 V ~ 50 HZ
POWER CONSUMPTION
110 W
EXTERNAL FUSE RATING
3A
INTERNAL FUSE
F1 - 3.15 A (20 mm to BS 4265)
DRY WEIGHT
28 kg
WATER CONTENT C.H.
0.8 litre
WATER CONTENT
0.2 litre
GAS SUPPLY CONNECTION
15 mm compression isolating valve
FLOW CONNECTION C.H.
22 mm compression isolating valve
RETURN CONNECTION C.H.
22 mm compression isolating valve
INLET CONNECTION D.H.W.
15 mm compression isolating valve
OUTLET CONNECTION D.H.W.
15 mm compression valve
SAFETY DISCHARGE C.H.
15 mm copper pipe
CONDENSATION DRAIN
3/4” (21.5 mm) push fi t over fl ow
MAX COLD WATER CAPACITY WITHOUT ADDITIONAL EXPANSION VESSEL 110 LITRE
SEALED WATER SYSTEM C.H.
MAX PRESSURE PHS
2.5 bar
MINIMUM WORKING PRESSURE
0.5 bar
7 LITRES EXPANSION VESSEL PRE-CHARGE-PRESSURE
0.5 bar
CENTRAL HEATING OPERATING TEMPERATURE MAX 80 °C min 35 °C
DESIGN FLOW RATE 1066 I/h 20 °C RISE
MINIMUM FLOW RATE C.H. 350 I/h
D.H.W. FLOW RATE 30 °C rise
11.9 l/min
D.H.W. FLOW RATE 35 °C rise
10.2 l/min
D.H.W. FLOW RATE 40 °C rise
8.9 l/min 10°C inlet temperature
D.H.W. TEMPERATURE
Max 60 °C min 35 °C
FAN SPEED D.H.W.
Max 4800 rpm - 160 Hz
min 1300 rpm - 43 Hz
Qmw Input Net
Max 25.4 kW
min 3.7 kW
D.H.W. PRESSURE PMW
Max 6.5 bar
D.H.W. PRESSURE PMW
min 0.5 bar
D.H.W. MINIMUM FLOW RATE
2.5 I/min
FLUE OUTLET NOM. DIAMETER 100 mm specially supplied with boilers (If required)
DESTINATION: GB, IE
CATEGORY II
2H3P
FLUE TYPE - C
13
- C
33
- C
53
NO
X
5
SEDBUK A IP X4 D
3
TECHNICAL DATA
CS 80 (T)
TABLE 3/A
NATURAL GAS (G 20)
П
2H3P
14
Summary of Contents for CS 80 T
Page 2: ...2 ...
Page 21: ...21 4 10 FLUE TERMINAL POSITION ...
Page 54: ...10 ELECTRICAL SYSTEM DIAGRAM 54 Fig 56 ...
Page 55: ...55 11 SPARE PARTS Fig 57 ...
Page 61: ...61 ...
Page 62: ...62 ...
Page 64: ...64 FLOWCHART FOR CO LEVEL AND COMBUSTION RATIO CHECK ON COMMISSIONING A CONDENSING BOILER ...
Page 65: ...65 12 1 ANALYSER CHECK LIST ...