IMPORTANT: Please lubricate the
internal part of the seals before
fitting.
26
TYPE OF FLUE SYSTEM (All types) - minimum and maximum distance
TABLE 5
Flue type C
13
C
33
C
53
1
Flue Diameter 60/100 80/125 60/100 80/125 80 mm
(concentric) (concentric) (concentric) (concentric) single pipe
Minimum length (m) 0.3 0.3 1.0 1.0 0.5
(horizontal length) (horizontal length)
(horizontal length) (horizontal length) (vertical length) (vertical length)
Maximum length (m) 8.0 23.0 13.0 26.0 43.0
Equivalent length of 45° bend (m) 0.5 1.25 0.5 1.25 1.25
Equivalent length of 90° bend (m) 1.0 2.5 1.0 2.5 2.5
5.5 OPTIONAL EXTRAS
HORIZONTAL FLUE KIT BOX CONTAINING
(Fig 10):
57 - Elbow header
59 - Rubber seal Ø 60
56 - Rubber seal Ø 100
60 - Fumes sample point
61 - Flue exhaust duct
62 - Air intake duct
69 - Air sample point
127 - Terminal Rubber wall seal
Fig 11
Fig 10
WARNING:
With horizontal concentric fl ue, the maximum
fl ue, the maximum
fl ue length is 8 metres
fl ue length is 8 metres, duct extension can be used with
the standard fl ue (see table 5).
FLUE EXTENSION BOX CONTAINING (Fig. 11):
1000 mm fl ue extension duct as an extra cost only
when requested for side and vertical fl ue applications.
59 - Rubber seal Ø 60
63 - Air intake duct extension
64 - Flue exhaust duct extension
Generally speaking, oils and greases are not
suitable for the “peroxide -EPDM”,
therefore we suggest a correct lubrication
using silicon-substances, for instance
“Silikon Spray“ (Arexons).
Summary of Contents for CS 80 T
Page 2: ...2 ...
Page 21: ...21 4 10 FLUE TERMINAL POSITION ...
Page 54: ...10 ELECTRICAL SYSTEM DIAGRAM 54 Fig 56 ...
Page 55: ...55 11 SPARE PARTS Fig 57 ...
Page 61: ...61 ...
Page 62: ...62 ...
Page 64: ...64 FLOWCHART FOR CO LEVEL AND COMBUSTION RATIO CHECK ON COMMISSIONING A CONDENSING BOILER ...
Page 65: ...65 12 1 ANALYSER CHECK LIST ...