USER’S GUIDE
CSI SYSTEM AAA (T) 780 SERIES
WITH OR WITHOUT BUILT IN TIMER
CONDENSING SYSTEM INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC MODULATING
COMBINATION BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
1
It is the law that all gas appliances are installed by
a competent person, in accordance with the gas
safety installation and use current regulations.
To the current Gas Safety (Installation and Use)
Regulations B.S. 5440:2 - (2000).
All registered installers carry a I.D. card and
have a registration number. Both should be re-
corded in your boiler log book. You can che-
ck
your installer by the gas safe register
.
Escape of gas
Should a gas leak be suspected, contact your gas
supplier without delay.
Do NOT search for space gas leaks with a naked
fl ame.
WARNING: This appliance must be earthed.
Do not touch or tamper with this sealed unit or its
components.
1 INTRODUCTION
1.1 Please carefully read the information in the
booklet to help you gain maximum if from your
appliance with minimum trouble.
1.1.1 Your Ravenheat Condensing Combination
Boiler has been designed to supply your Central
Heating and Domestic Hot Water directly from one
unit. When central Heating is operating, the
circulation will be interrupted when domestic hot
water is being drawn off. This will normally not
affect the level of the heating.
1.2 CLEARANCES AROUND THE BOILER
Above 125mm (5 inches)
Below 150mm (6 inches)
Front 450mm (18 inches)
Sides 5mm (0.2 inches)
25mm (1 inch) at the front when installed
in a cupboard.
PLEASE NOTE
Due to the high effi ciency and resulting low fl ue gas
exhaust temperature a white plume of condensation
vapour (cool steam) will be emitted from the fl ue outlet
terminal, this is quite normal. It will be particularly
evident during periods of low outdoor temperatures or
when the boiler is working at its optimum performance.
1.2.1 Minimum clearances are required for safety and
maintenance.
Do not obstruct any purpose made ventilation opening
if boiler has been fi tted in a compartment. Never hang
clothes, etc., over the appliance.
1.3 USER CONTROLS
(See Fig. 1)
1.3.1 This appliance is designed to operate with the
minimum of attention by the user.
All controls are to be found on the control panel.
1.4 OPERATING SAFETY CHECKS TO
PROTECT YOUR APPLIANCE
1.4.1 Before lighting the appliance check central
heating system pressure ( (7) is not less than 1 bar
gauge. If it is below this do not light but consult your
installer about refi lling your system as you may have a
leak in the system.
1.4.2 A RED warning light on the control panel (8)
warns of a fl ame failure of the burner. This can be reset
manually by pressing mains boiler on/off switch (1).
1.4.3 A RED warning intermittence light on the control
panel (8) warns of a high temperature lockout on the
overheat thermostat. This could occur due to air or poor
circulation in the boiler/heating circuit. This can be reset
manually by pressing mains boiler on/off switch (1). If
lockout should persist leave the appliance shut down
and consult your installer/service engineer
immediately.
1.4.4 The CSI SYSTEM AAA(T) 780 series condensing
boiler is fi tted with a condensate outlet which must be
connected by the installer to a suitable discharge point
as specifi ed in the installation manual.
On no account should this discharge pipe be blocked
or modifi ed.