M7 GX Technical Manual 

7

 

Raveon Technologies Corp. 

7.1. 

GPS Additional Commands to Configure GPS and Tracking Features 

The following commands are unique to the –

GX

 version of the 

M7

.  When you execute any of these 

commands, the new parameter is automatically stored in EEPROM.   

Command

 

Command Description

 

Parameters

 

Default 

 

GX 

Display GPS settings.

  Show an overview of the current GPS features and 

configurations in the M7 GX.  

GPS 

GPS Operation Mode.

  Read/Set the GX version’s Operating mode. 

0 - 6 

GPS&F 

Reset all GPS (-GX version) parameters.

  Set the GX version’s Operating 

mode to GPS mode 4, and sets all GPS parameters to factory defaults. It 
does not erase frequency or other radio-related parameters.  

IDLERATE 

IDLE TX Interval.

  Set the number of seconds between position transmissions 

when the unit is idle (has not moved more than TRIGDX meters). 

0-9999 

seconds 

10 

KEYPHRASE 

Privacy Security Key Code.

  Set the privacy key for this device.  It must be 

the same key as used on all other Raveon products in your system.  It 
secures radio transmissions from unauthorized reception. Set it to 0 to disable 
security encryption of data.  

2-16 ASCII 
characters. 

“RAVEON” 

PREFIX 

ID Prefix.

  Set an ID prefix.  The prefix is 1-8 characters that will be put in 

front of the ID when reporting an ID as a waypoint name. A dash means no 
prefix. Default is a capitol letter V. 

1-8 ASCII characters 

Set it to “0” for no 

prefix. 

SLOTTIME 

TDMA Slot duration.

 Configure the width of a TDMA slot.  50mS increments.  

 

50 - 1000 

200 

SLOTNUM 

TDMA Slot Number.

 Configure the slot number that this radio will use to send 

its data in. 

 

1-9999 

The MYID of 

the unit 

TRIGBITS 

I/O Change Reporting.

  Which bits are used as transmission triggers.  This is 

a HEX number.  Bit 0 is IN0, bit 1 is IN1….

 

0-FF 

TDMATIME 

Set/read TDMA Frame time.

  The length of one TDMA time frame, in 

seconds.  M7’s may transmit once per frame, and only in their preset time-
slot.  

1-3599 

10 

TRIGPOL 

Polarity of the input bits.

  0 = normal active high operation(causes unit to 

transmit when it goes high), 1 = Inverted, active low.  This is a HEX number.  
Bit 0 is IN0, bit 1 is IN1….

 

0-FF 

Active high 

TRIGEX 

Report on change.

  Sets which input bits cause a report on change.  If a 

particular bit is a 1, then it will trigger a report when it changes.  The input bit 
must also be enable with the TRIGBITS. This is a HEX number.  Bit 0 is IN0, 
bit 1 is IN1…

 

0-FF 

TRIGDX 

Distance trigger.

  Set a distance (in meters) threshold beyond-which the unit 

will transmit its position and status. If set to 0, the unit always reports at the 
TXRATE.  If set to an distance greater than zero, then the unit reports at the 
TXRATE intervals if it has moved this distance since the last report.  If it has 
not moved, it will still report its position, but at the rate set by IDLERATE.  If 
IDLERATE is set t 0, then the unit will not report its position when not moving.

 

0-999 

TRIGSPEED 

Speeding Report.

  Set a speed (in kilometers/hour) threshold above-which 

the unit will begin reporting its position and status. Set to 0 to disable this 
feature. 

 

0-999 

TXRATE 

GPS Report Rate.

  Set number of seconds between GPS reports.  This is 

also the rate at which the internal GPS will measure position, speed, etc.  
Even if the unit is not moving, the GPS periodically measures position and 
speed to determine if it has triggered a speed or position transmission.  

1 - 9999 

10 

 

 

7.2. 

Factory Default Settings 

For the UHF 

M7 GX

 model RV-M7-UC-GX, the factory defaults GPS settings are: 

Radio channel 1    .................464.500 MHz  

Slot Number............................The same ID 

GPS Mode ............................4 (GPS display) 

ID Prefix ..................................V 

Over-the-air baud rate:..........4800 baud, 2-level 

I/O Change reporting ..............0, off 

Serial port.............................. 4800  N/8/1 

Proximity Alert.........................0, off 

Hardware flow control ...........Off 

Security KEY...........................RAVEON 

RF Power Output ..................5 watts 

Position  report interval ...........10 seconds 

Channel number ...................1  

 

Summary of Contents for RV-M7 GX WX

Page 1: ...Technologies Corp RV M7 GX G P S T r a n sp o n d e r Quick Start Guide Version C0 February 2010 RV M7 GX RV M7 GX WX Raveon Technologies Corporation 990 Park Center Drive Suite C Vista CA 92081 www...

Page 2: ...and a radio modem for sending and receiving data The M7 GX may be configured for a number of different GPS applications including Transponder Periodically transmit position and status TX only RavTrack...

Page 3: ...transponders within radio range GPS 5 LX No GPS module Lowrance and Garmin GPS displays Radar displays Mobile displays 38400 PRAVE Connect the M7 GX to a PC running RavTrack PC or change the message t...

Page 4: ...reporting GND or floating for a 0 3V for digital 1 8 CTS out Clear to send Used to stop the flow of data going into the RxD pin from the device connected to the M7 0 OK to send 1 don t send 9 Power In...

Page 5: ...eters Factory Default ATBD Baud Rate Sets serial com port baud rate bps Over the air throughput baud rate is set with ATR2 command If a PC s serial baud rate is set higher than the fixed over the air...

Page 6: ...ATRV Disable Remote Access When enabled set to a 0 the modem will respond to over the air RPR requests Pings and over the air commands 0 Remote Access on 1 Remote Access disabled 1 ATSL Serial Number...

Page 7: ...e The length of one TDMA time frame in seconds M7 s may transmit once per frame and only in their preset time slot 1 3599 10 TRIGPOL Polarity of the input bits 0 normal active high operation causes un...

Page 8: ...s the KEYPHRASE programmed into all the other M7 GX transponders in your system The factory default KEYPHRASE is RAVEON call capitols 12 To see an overview of how the modem is configured use the SHOW...

Page 9: ...GX transponders at ID 0001 The second M7 should be ID 0002 and so on The M7 GX transponders have internal clocks with 20 ticks per second They can measure time and initiate transmissions 20 times ever...

Page 10: ...with the antenna and properly ground the antenna and the M7 chassis to an earth ground 8 Connect Digital Inputs The stock M7 GX has up to 3 digital inputs using the input pins of the RS 232 serial por...

Page 11: ...ta communication via RS232 also Capable of Speed triggered position reports Speed Trigger default Minimum Distance Trigger Digital Input Triggers Serial Port Baud Rate Can be a repeater Command used t...

Page 12: ...Manual 12 Raveon Technologies Corp For Technical Assistance email or call Raveon at Raveon Technologies Corporation 990 Park Center Drive Suite C Vista CA 92081 760 727 8004 www raveontech com sales...

Reviews: