14
Symptoms
3. Will not operate
Cause
1. CF not operating
Correction
1. Check green circuit
in Forward
Control
See "Checking
Circuits"
2. CF normally open
Contacts not making
contact
2. Visually check
contacts. UNPLUG BAT-
TERIES. File contacts
with point file.
Replace contactor, if
necessary.
3. CR normally closed
Contacts not making
contact
3. Same as 2
4. Will not operate
in Reverse
1. CR not operating
1. Check orange circuit.
See "Checking
Control Circuits"
2. CR normally open
Contacts not making
contact
2. Visually check contacts.
UNPLUG POWER TO
MOTOR. File contacts
with point file.
Replace contactor, if
necessary.
3. CF normally closed
Contacts not making
contact.
3. Same as 2
5. Electrolysis --
rapid corrosion on
underwater parts of
motor where paint
is off.
1. Boat grounded to a
battery terminal --
such as through the
base of an automotive
type light. Some
marine running lights
also connected through
base.
1. Eliminate ground by
insulating light from
boat or eliminate
light. NEVER ground
boat when a Ray Out-
board System is
installed.
See Electrolysis
6. Charger will not
1. One or both diodes
1. Check diodes with
charge ("0" ammeter
have failed due to
ohmmeter and replace