16
Symptoms
Cause
Correction
4. Battery acid
4. Replace batteries.
allowed to remain
See Operating and
below plates (pre-
Maintenance Instructions
mature failure).
for care of batteries.
5. Battery life
5. Replace batteries.
expired (4 to 6 years
typical for private
use).
6. One battery reversed
6. Check to see that
(connected plus to plus
batteries are all wired
instead of plus to
in series plus to
minus.)
minus. Reversed
battery may have to be
replaced. First, try to
bring it up to charge
with a 6 volt charger.