The Rayburn 355M is intended to supply heating for:-
(a)
Cooking and domestic hot water.
(b)
Cooking, domestic hot water and central heating.
Air for combustion within the firebox is obtained from two
sources viz:-
a) When the appliance is being used for cooking and domestic
hot water only, the rate of burning is determined by the
manually operated spinwheel control on the ashpit door.
b) When central heating is also required, close the spinwheel
control and operate the burning rate by means of the boiler
thermostat.
The cooker has both boiler and cooker flues which are
opened/closed by internal dampers working in conjunction and
operated manually by the cooker/boiler damper at the front of
the cooker.
The setting should be relative to the services required, viz:-
H
for all services,
C
for cooking and domestic hot water only.
REMEMBER, when replacing a part on this appliance, use only
spare parts that you can be assured conform to the safety and
performance specification that we require. Do not use
reconditioned or copy parts that have not been clearly
authorised by AGA.
Installation Instructions for
Rayburn Heatranger 355M
Solid Fuel and
Wood Burning Cooker
PERFORMANCE
10/05 EINS 511025
DESN 510291
DESN 510278 B
Consumer Protection Act 1987
As responsible manufacturers we take care to make sure that our
products are designed and constructed to meet the required safety
standards when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE
ACCOMPANYING WARRANTY.
Any alteration that is not approved by Aga, could invalidate the
approval of the appliance, operation of the warranty and could also
affect your statutory rights.
Control of Substances - Health and Safety
Important
This appliance may contain some of the materials that are indicated.
It is the Users/Installers responsibility to ensure that the necessary
personal protective clothing is worn when handling, where
applicable, the pertinent parts that contain any of the listed materials
that could be interpreted as being injurious to health and safety, see
below for information.
Firebricks, Fuel beds, Artificial Fuels -
when handling use
disposable gloves.
Fire Cement -
when handling use disposable gloves.
Glues and Sealants -
exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil -
may be harmful if inhaled, may be irritating to skin,
eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face-masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product, reduce dust with water spray,
ensure that parts are securely wrapped.
WARNING
THE ASHPIT AND FIREBOX DOORS MUST BE
LOCKED CLOSED AT ALL TIMES DURING NORMAL
USE, EXCEPT WHEN LIGHTING OR RE-FUELLING.
Better than you ever imagined