Site requirements - Flue terminal location
FIG. 12 - Location of flue terminal
A
DIRECTLY BELOW AN OPENING, AIR
600mm
BRICK, OPENING WINDOW etc.
B
HORIZONTALLY TO AN OPENING, AIR
600mm
BRICK, OPENING WINDOW etc.
C
BELOW A GUTTER, EAVES OR BALCONY 75mm
WITH PROTECTION
D
BELOW A GUTTER OR A BALCONY
600mm
WITHOUT PROTECTION
E
FROM VERTICAL SANITARY PIPEWORK
300mm
F
FROM AN INTERNAL OR EXTERNAL
300mm
CORNER
G
ABOVE GROUND OR BALCONY LEVEL
300mm
H
FROM A SURFACE OR A BOUNDARY
600mm
FACING THE TERMINAL
J
FROM A TERMINAL FACING THE
1200mm
TERMINAL
K
VERTICALLY FROM A TERMINAL
1500mm
ON THE SAME WALL
L
HORIZONTALLY FROM A TERMINAL ON
750mm
THE SAME WALL
12
DISTANCES STATED ARE MINIMUM ALLOWABLE REQUIREMENTS