Take precautions if installation is incomplete at end of
work day.
At the end of the work day:
• Ensure that there are no exposed connectors. Each
sensing cable should be connected to a Modular
Leader Cable (TT-MLC-MC), Modular End Termination
(TT-MET-MC), and/or other sensing cables; check both
ends of the cable.
• Test and record the condition of installed sensing cable
following the Sensing Cable Test Procedure.
• If practical, connect the installed sensing cable
to the TraceTek alarm module. Test the system
and put it in operation following the alarm module
installation instructions.
At the beginning of the next work day:
• Check that the installed sensing cable is clean and intact
following the Sensing Cable Test Procedure. Compare
the results with those obtained at the end of the previous
work day. If necessary, investigate and correct problems
before proceeding.